Laydyne

Northstar Cold-chain Cross-dock — detailed capacity study

Compare complete saved layouts, with the evidence and questions needed for a decision.

Cost conditions, when included, are conditional arithmetic. No realized ROI or dynamic simulation result is claimed. The input hashes link the drawings, quantities and changes to each saved option; they are consistency checks, not proof of authenticity.

Drawing sheets and inventory limited to: NX-L1, NX-L2. Evaluations, totals and changes cover each entire saved layout.

Decision and next checks

Compare the stated capacity and layout changes under identical demand.

The conditions are incomplete. No option is recommended.

OptionRecorded conditionsOpen checks
Detailed · 3 carriers · 2 inspection · 2 packing slotsNeeds confirmationCriteria not registered
Detailed · 6 carriers · 3 inspection · 4 packing slotsNeeds confirmationCriteria not registered

Confirm before choosing

The same baseline conditions are applied to all saved options. This compares only the supplied drawings and criteria; assumptions still need confirmation.

Definitions and evaluation version

design-static-1 · fnv1a-9c49227a

IDConditionDefinition

Baseline · Detailed · 3 carriers · 2 inspection · 2 packing slots

inputHash: fnv1a-b24498c7 · spaceHash: fnv1a-fc82ac11

Saved: 2026-10-15T10:37:26.695Z

Purpose and decision

Synthetic operational planning example: Northstar Cold-chain Cross-dock

Compare the stated capacity and layout changes under identical demand.

Prepared for: Facility operations planner

Source material

IDTitle / kindReferenceNote
syntheticSynthetic operating brief (assumption)—No real site measurements, certification, demand forecast or ROI.

Provided facts, assumptions and unknowns

ItemStatusValueSourceCritical to the decision
Operating assumption 1AssumedTwo 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.synthetic—
Operating assumption 2Assumed24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.synthetic—
Operating assumption 3Assumed120 loads at 15 s intervals; two-hour observation.synthetic—
Operating assumption 4AssumedInspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.synthetic—
Operating assumption 5AssumedCarriers hold loads through all steps and return empty before becoming available.synthetic—
Operating assumption 6AssumedThe staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.synthetic—

Requirements to check

Written requirements are not automatically verified. Unknowns need confirmation before a decision.

2D drawings

Each sheet shows this saved option. The overview preserves real floors and buildings; alternatives are never drawn as additional floors.

L1 · Receiving, chilled storage and dispatch — floor plan
L1 · Receiving, chilled storage and dispatch — floor plan · NX-L1 · A3 · 1:600

inputHash: fnv1a-b24498c7 · spaceHash: fnv1a-fc82ac11

L2 · Quality laboratory and staff operations — floor plan
L2 · Quality laboratory and staff operations — floor plan · NX-L2 · A3 · 1:600

inputHash: fnv1a-b24498c7 · spaceHash: fnv1a-fc82ac11

3D overview

3D was not requested. The 2D drawings are included.

Quantities from the drawn model

inputHash: fnv1a-b24498c7 · spaceHash: fnv1a-fc82ac11

Floor area follows the drawn outline less holes; walls are not subtracted. Overlapping floors are counted twice. These are not surveyed or legal floor areas. Dimensions are metres; areas are square metres.

FloorArea (m²)Zoned (m²)All parts
Receiving, chilled storage and dispatch (NX-L1)138242391.4445
Quality laboratory and staff operations (NX-L2)138243752410
KindCount
crate_stack106
sign96
chair76
zone75
machine64
workbench60
screen52
rack50
shelf42
platform_trolley42
cabinet36
wall26
dock_door24
person24
fridge18
washbasin18
window16
table10
sofa8
round_table4
gate4
planter4
Part inventory (855)

inputHash: fnv1a-b24498c7 · spaceHash: fnv1a-fc82ac11

Includes all parts, zones and structure. The kind is a drawing primitive; tags, labels and notes identify the equipment role. CSV and JSON preserve every row.

IDLabel / kindFloor / buildingTagsSource / noteW × D × H (m)x, z, y (m)
wall-1Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations144 × 0.2 × 40, 0, 0
gate-1Gate (gate)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6 × 0.2 × 269, 0, 0
wall-2Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations144 × 0.2 × 40, 95.8, 0
gate-2Gate (gate)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6 × 0.2 × 269, 95.8, 0
wall-3Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.2 × 95.6 × 40, 0.2, 0
wall-4Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.2 × 95.6 × 4143.8, 0.2, 0
spineMaterial movement spine (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationspassageassumed · Synthetic dimensions; confirm against a measured site plan.12 × 88 × 0.0267, 4, 0
rack-1-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 20, 0
rack-1-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 20, 0
rack-1-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 20, 0
rack-1-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 20, 0
rack-1-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 20, 0
rack-1-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 20, 0
rack-1-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 20, 0
rack-1-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 20, 0
rack-1-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 20, 0
rack-1-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 20, 0
rack-2-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 32, 0
rack-2-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 32, 0
rack-2-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 32, 0
rack-2-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 32, 0
rack-2-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 32, 0
rack-2-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 32, 0
rack-2-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 32, 0
rack-2-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 32, 0
rack-2-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 32, 0
rack-2-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 32, 0
rack-3-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 44, 0
rack-3-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 44, 0
rack-3-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 44, 0
rack-3-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 44, 0
rack-3-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 44, 0
rack-3-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 44, 0
rack-3-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 44, 0
rack-3-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 44, 0
rack-3-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 44, 0
rack-3-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 44, 0
rack-4-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 56, 0
rack-4-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 56, 0
rack-4-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 56, 0
rack-4-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 56, 0
rack-4-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 56, 0
rack-4-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 56, 0
rack-4-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 56, 0
rack-4-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 56, 0
rack-4-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 56, 0
rack-4-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 56, 0
rack-5-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 68, 0
rack-5-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 68, 0
rack-5-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 68, 0
rack-5-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 68, 0
rack-5-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 68, 0
rack-5-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 68, 0
rack-5-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 68, 0
rack-5-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 68, 0
rack-5-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 68, 0
rack-5-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 68, 0
workbench-1Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 22, 0
shelf-1Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 22, 0
platform_trolley-1Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 25.5, 0
workbench-2Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 22, 0
shelf-2Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 22, 0
platform_trolley-2Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 25.5, 0
workbench-3Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 22, 0
shelf-3Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 22, 0
platform_trolley-3Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 25.5, 0
workbench-4Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 22, 0
shelf-4Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 22, 0
platform_trolley-4Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 25.5, 0
workbench-5Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 22, 0
shelf-5Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 22, 0
platform_trolley-5Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 25.5, 0
workbench-6Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 22, 0
shelf-6Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 22, 0
platform_trolley-6Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 25.5, 0
workbench-7Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 37, 0
shelf-7Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 37, 0
platform_trolley-7Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 40.5, 0
workbench-8Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 37, 0
shelf-8Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 37, 0
platform_trolley-8Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 40.5, 0
workbench-9Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 37, 0
shelf-9Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 37, 0
platform_trolley-9Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 40.5, 0
workbench-10Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 37, 0
shelf-10Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 37, 0
platform_trolley-10Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 40.5, 0
workbench-11Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 37, 0
shelf-11Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 37, 0
platform_trolley-11Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 40.5, 0
workbench-12Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 37, 0
shelf-12Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 37, 0
platform_trolley-12Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 40.5, 0
workbench-13Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 52, 0
shelf-13Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 52, 0
platform_trolley-13Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 55.5, 0
workbench-14Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 52, 0
shelf-14Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 52, 0
platform_trolley-14Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 55.5, 0
workbench-15Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 52, 0
shelf-15Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 52, 0
platform_trolley-15Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 55.5, 0
workbench-16Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 52, 0
shelf-16Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 52, 0
platform_trolley-16Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 55.5, 0
workbench-17Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 52, 0
shelf-17Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 52, 0
platform_trolley-17Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 55.5, 0
workbench-18Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 52, 0
shelf-18Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 52, 0
platform_trolley-18Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 55.5, 0
workbench-19Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 67, 0
shelf-19Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 67, 0
platform_trolley-19Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 70.5, 0
workbench-20Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 67, 0
shelf-20Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 67, 0
platform_trolley-20Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 70.5, 0
workbench-21Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 67, 0
shelf-21Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 67, 0
platform_trolley-21Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 70.5, 0
workbench-22Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 67, 0
shelf-22Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 67, 0
platform_trolley-22Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 70.5, 0
workbench-23Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 67, 0
shelf-23Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 67, 0
platform_trolley-23Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 70.5, 0
workbench-24Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 67, 0
shelf-24Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 67, 0
platform_trolley-24Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 70.5, 0
dock_door-1Inbound bay 1 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 47, 0, 0
dock_door-2Outbound bay 1 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 47, 95.75, 0
dock_door-3Inbound bay 2 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 417, 0, 0
dock_door-4Outbound bay 2 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 417, 95.75, 0
dock_door-5Inbound bay 3 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 427, 0, 0
dock_door-6Outbound bay 3 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 427, 95.75, 0
dock_door-7Inbound bay 4 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 437, 0, 0
dock_door-8Outbound bay 4 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 437, 95.75, 0
dock_door-9Inbound bay 5 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 447, 0, 0
dock_door-10Outbound bay 5 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 447, 95.75, 0
dock_door-11Inbound bay 6 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 457, 0, 0
dock_door-12Outbound bay 6 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 457, 95.75, 0
dock_door-13Inbound bay 7 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 467, 0, 0
dock_door-14Outbound bay 7 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 467, 95.75, 0
dock_door-15Inbound bay 8 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 477, 0, 0
dock_door-16Outbound bay 8 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 477, 95.75, 0
dock_door-17Inbound bay 9 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 487, 0, 0
dock_door-18Outbound bay 9 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 487, 95.75, 0
dock_door-19Inbound bay 10 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 497, 0, 0
dock_door-20Outbound bay 10 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 497, 95.75, 0
dock_door-21Inbound bay 11 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4107, 0, 0
dock_door-22Outbound bay 11 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4107, 95.75, 0
dock_door-23Inbound bay 12 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4117, 0, 0
dock_door-24Outbound bay 12 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4117, 95.75, 0
receivingReceiving handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 10, 0
inspectionQuality sample handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 26, 0
cold-storeCold-store handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 45, 0
packingPacking handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 65, 0
dispatchDispatch handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 85, 0
mover-homeCarrier parking (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0264, 10, 0
dock_door-1-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.026.7, 3, 0
dock_door-1-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.057.3, 4.4, 0
dock_door-1-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.059.5, 4.4, 0
dock_door-1-numberIN 01 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.47.4, 0.21, 3.1
dock_door-2-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.026.7, 88, 0
dock_door-2-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.057.3, 89.4, 0
dock_door-2-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.059.5, 89.4, 0
dock_door-2-numberOUT 01 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.47.4, 95.74, 3.1
dock_door-3-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0216.7, 3, 0
dock_door-3-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0517.3, 4.4, 0
dock_door-3-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0519.5, 4.4, 0
dock_door-3-numberIN 02 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.417.4, 0.21, 3.1
dock_door-4-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0216.7, 88, 0
dock_door-4-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0517.3, 89.4, 0
dock_door-4-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0519.5, 89.4, 0
dock_door-4-numberOUT 02 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.417.4, 95.74, 3.1
dock_door-5-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0226.7, 3, 0
dock_door-5-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0527.3, 4.4, 0
dock_door-5-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0529.5, 4.4, 0
dock_door-5-numberIN 03 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.427.4, 0.21, 3.1
dock_door-6-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0226.7, 88, 0
dock_door-6-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0527.3, 89.4, 0
dock_door-6-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0529.5, 89.4, 0
dock_door-6-numberOUT 03 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.427.4, 95.74, 3.1
dock_door-7-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0236.7, 3, 0
dock_door-7-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0537.3, 4.4, 0
dock_door-7-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0539.5, 4.4, 0
dock_door-7-numberIN 04 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.437.4, 0.21, 3.1
dock_door-8-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0236.7, 88, 0
dock_door-8-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0537.3, 89.4, 0
dock_door-8-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0539.5, 89.4, 0
dock_door-8-numberOUT 04 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.437.4, 95.74, 3.1
dock_door-9-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0246.7, 3, 0
dock_door-9-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0547.3, 4.4, 0
dock_door-9-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0549.5, 4.4, 0
dock_door-9-numberIN 05 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.447.4, 0.21, 3.1
dock_door-10-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0246.7, 88, 0
dock_door-10-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0547.3, 89.4, 0
dock_door-10-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0549.5, 89.4, 0
dock_door-10-numberOUT 05 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.447.4, 95.74, 3.1
dock_door-11-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0256.7, 3, 0
dock_door-11-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0557.3, 4.4, 0
dock_door-11-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0559.5, 4.4, 0
dock_door-11-numberIN 06 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.457.4, 0.21, 3.1
dock_door-12-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0256.7, 88, 0
dock_door-12-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0557.3, 89.4, 0
dock_door-12-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0559.5, 89.4, 0
dock_door-12-numberOUT 06 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.457.4, 95.74, 3.1
dock_door-13-numberIN 07 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.467.4, 0.21, 3.1
dock_door-14-numberOUT 07 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.467.4, 95.74, 3.1
dock_door-15-numberIN 08 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.477.4, 0.21, 3.1
dock_door-16-numberOUT 08 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.477.4, 95.74, 3.1
dock_door-17-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0286.7, 3, 0
dock_door-17-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0587.3, 4.4, 0
dock_door-17-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0589.5, 4.4, 0
dock_door-17-numberIN 09 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.487.4, 0.21, 3.1
dock_door-18-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0286.7, 88, 0
dock_door-18-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0587.3, 89.4, 0
dock_door-18-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0589.5, 89.4, 0
dock_door-18-numberOUT 09 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.487.4, 95.74, 3.1
dock_door-19-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0296.7, 3, 0
dock_door-19-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0597.3, 4.4, 0
dock_door-19-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0599.5, 4.4, 0
dock_door-19-numberIN 10 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.497.4, 0.21, 3.1
dock_door-20-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0296.7, 88, 0
dock_door-20-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0597.3, 89.4, 0
dock_door-20-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0599.5, 89.4, 0
dock_door-20-numberOUT 10 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.497.4, 95.74, 3.1
dock_door-21-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02106.7, 3, 0
dock_door-21-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05107.3, 4.4, 0
dock_door-21-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05109.5, 4.4, 0
dock_door-21-numberIN 11 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4107.4, 0.21, 3.1
dock_door-22-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02106.7, 88, 0
dock_door-22-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05107.3, 89.4, 0
dock_door-22-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05109.5, 89.4, 0
dock_door-22-numberOUT 11 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4107.4, 95.74, 3.1
dock_door-23-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02116.7, 3, 0
dock_door-23-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05117.3, 4.4, 0
dock_door-23-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05119.5, 4.4, 0
dock_door-23-numberIN 12 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4117.4, 0.21, 3.1
dock_door-24-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02116.7, 88, 0
dock_door-24-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05117.3, 89.4, 0
dock_door-24-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05119.5, 89.4, 0
dock_door-24-numberOUT 12 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4117.4, 95.74, 3.1
rack-1-1-numberCHILL 01 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 27.01, 1.75
rack-1-2-numberCHILL 02 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 27.01, 1.75
rack-1-3-numberCHILL 03 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 27.01, 1.75
rack-1-4-numberCHILL 04 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 27.01, 1.75
rack-1-5-numberCHILL 05 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 27.01, 1.75
rack-1-6-numberCHILL 06 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 27.01, 1.75
rack-1-7-numberCHILL 07 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 27.01, 1.75
rack-1-8-numberCHILL 08 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 27.01, 1.75
rack-1-9-numberCHILL 09 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 27.01, 1.75
rack-1-10-numberCHILL 10 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 27.01, 1.75
rack-2-1-numberCHILL 11 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 39.01, 1.75
rack-2-2-numberCHILL 12 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 39.01, 1.75
rack-2-3-numberCHILL 13 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 39.01, 1.75
rack-2-4-numberCHILL 14 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 39.01, 1.75
rack-2-5-numberCHILL 15 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 39.01, 1.75
rack-2-6-numberCHILL 16 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 39.01, 1.75
rack-2-7-numberCHILL 17 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 39.01, 1.75
rack-2-8-numberCHILL 18 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 39.01, 1.75
rack-2-9-numberCHILL 19 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 39.01, 1.75
rack-2-10-numberCHILL 20 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 39.01, 1.75
rack-3-1-numberCHILL 21 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 51.01, 1.75
rack-3-2-numberCHILL 22 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 51.01, 1.75
rack-3-3-numberCHILL 23 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 51.01, 1.75
rack-3-4-numberCHILL 24 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 51.01, 1.75
rack-3-5-numberCHILL 25 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 51.01, 1.75
rack-3-6-numberCHILL 26 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 51.01, 1.75
rack-3-7-numberCHILL 27 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 51.01, 1.75
rack-3-8-numberCHILL 28 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 51.01, 1.75
rack-3-9-numberCHILL 29 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 51.01, 1.75
rack-3-10-numberCHILL 30 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 51.01, 1.75
rack-4-1-numberCHILL 31 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 63.01, 1.75
rack-4-2-numberCHILL 32 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 63.01, 1.75
rack-4-3-numberCHILL 33 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 63.01, 1.75
rack-4-4-numberCHILL 34 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 63.01, 1.75
rack-4-5-numberCHILL 35 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 63.01, 1.75
rack-4-6-numberCHILL 36 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 63.01, 1.75
rack-4-7-numberCHILL 37 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 63.01, 1.75
rack-4-8-numberCHILL 38 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 63.01, 1.75
rack-4-9-numberCHILL 39 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 63.01, 1.75
rack-4-10-numberCHILL 40 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 63.01, 1.75
rack-5-1-numberCHILL 41 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 75.01, 1.75
rack-5-2-numberCHILL 42 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 75.01, 1.75
rack-5-3-numberCHILL 43 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 75.01, 1.75
rack-5-4-numberCHILL 44 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 75.01, 1.75
rack-5-5-numberCHILL 45 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 75.01, 1.75
rack-5-6-numberCHILL 46 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 75.01, 1.75
rack-5-7-numberCHILL 47 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 75.01, 1.75
rack-5-8-numberCHILL 48 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 75.01, 1.75
rack-5-9-numberCHILL 49 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 75.01, 1.75
rack-5-10-numberCHILL 50 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 75.01, 1.75
workbench-1-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 21.5, 0
workbench-1-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 22.25, 0.9
workbench-1-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 22.7, 0.9
workbench-1-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 22.7, 0.9
workbench-1-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 23.05, 0.9
workbench-1-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 25.2, 0
workbench-2-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 21.5, 0
workbench-2-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 22.25, 0.9
workbench-2-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 22.7, 0.9
workbench-2-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 22.7, 0.9
workbench-2-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 23.05, 0.9
workbench-2-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 25.2, 0
workbench-3-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 21.5, 0
workbench-3-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 22.25, 0.9
workbench-3-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 22.7, 0.9
workbench-3-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 22.7, 0.9
workbench-3-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 23.05, 0.9
workbench-3-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 25.2, 0
workbench-4-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 21.5, 0
workbench-4-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 22.25, 0.9
workbench-4-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 22.7, 0.9
workbench-4-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 22.7, 0.9
workbench-4-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 23.05, 0.9
workbench-4-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 25.2, 0
workbench-5-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 21.5, 0
workbench-5-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 22.25, 0.9
workbench-5-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 22.7, 0.9
workbench-5-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 22.7, 0.9
workbench-5-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 23.05, 0.9
workbench-5-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 25.2, 0
workbench-6-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 21.5, 0
workbench-6-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 22.25, 0.9
workbench-6-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 22.7, 0.9
workbench-6-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 22.7, 0.9
workbench-6-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 23.05, 0.9
workbench-6-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 25.2, 0
workbench-7-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 36.5, 0
workbench-7-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 37.25, 0.9
workbench-7-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 37.7, 0.9
workbench-7-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 37.7, 0.9
workbench-7-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 38.05, 0.9
workbench-7-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 40.2, 0
workbench-8-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 36.5, 0
workbench-8-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 37.25, 0.9
workbench-8-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 37.7, 0.9
workbench-8-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 37.7, 0.9
workbench-8-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 38.05, 0.9
workbench-8-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 40.2, 0
workbench-9-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 36.5, 0
workbench-9-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 37.25, 0.9
workbench-9-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 37.7, 0.9
workbench-9-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 37.7, 0.9
workbench-9-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 38.05, 0.9
workbench-9-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 40.2, 0
workbench-10-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 36.5, 0
workbench-10-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 37.25, 0.9
workbench-10-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 37.7, 0.9
workbench-10-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 37.7, 0.9
workbench-10-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 38.05, 0.9
workbench-10-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 40.2, 0
workbench-11-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 36.5, 0
workbench-11-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 37.25, 0.9
workbench-11-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 37.7, 0.9
workbench-11-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 37.7, 0.9
workbench-11-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 38.05, 0.9
workbench-11-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 40.2, 0
workbench-12-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 36.5, 0
workbench-12-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 37.25, 0.9
workbench-12-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 37.7, 0.9
workbench-12-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 37.7, 0.9
workbench-12-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 38.05, 0.9
workbench-12-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 40.2, 0
workbench-13-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 51.5, 0
workbench-13-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 52.25, 0.9
workbench-13-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 52.7, 0.9
workbench-13-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 52.7, 0.9
workbench-13-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 53.05, 0.9
workbench-13-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 55.2, 0
workbench-14-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 51.5, 0
workbench-14-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 52.25, 0.9
workbench-14-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 52.7, 0.9
workbench-14-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 52.7, 0.9
workbench-14-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 53.05, 0.9
workbench-14-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 55.2, 0
workbench-15-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 51.5, 0
workbench-15-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 52.25, 0.9
workbench-15-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 52.7, 0.9
workbench-15-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 52.7, 0.9
workbench-15-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 53.05, 0.9
workbench-15-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 55.2, 0
workbench-16-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 51.5, 0
workbench-16-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 52.25, 0.9
workbench-16-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 52.7, 0.9
workbench-16-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 52.7, 0.9
workbench-16-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 53.05, 0.9
workbench-16-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 55.2, 0
workbench-17-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 51.5, 0
workbench-17-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 52.25, 0.9
workbench-17-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 52.7, 0.9
workbench-17-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 52.7, 0.9
workbench-17-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 53.05, 0.9
workbench-17-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 55.2, 0
workbench-18-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 51.5, 0
workbench-18-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 52.25, 0.9
workbench-18-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 52.7, 0.9
workbench-18-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 52.7, 0.9
workbench-18-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 53.05, 0.9
workbench-18-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 55.2, 0
workbench-19-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 66.5, 0
workbench-19-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 67.25, 0.9
workbench-19-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 67.7, 0.9
workbench-19-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 67.7, 0.9
workbench-19-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 68.05, 0.9
workbench-19-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 70.2, 0
workbench-20-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 66.5, 0
workbench-20-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 67.25, 0.9
workbench-20-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 67.7, 0.9
workbench-20-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 67.7, 0.9
workbench-20-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 68.05, 0.9
workbench-20-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 70.2, 0
workbench-21-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 66.5, 0
workbench-21-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 67.25, 0.9
workbench-21-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 67.7, 0.9
workbench-21-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 67.7, 0.9
workbench-21-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 68.05, 0.9
workbench-21-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 70.2, 0
workbench-22-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 66.5, 0
workbench-22-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 67.25, 0.9
workbench-22-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 67.7, 0.9
workbench-22-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 67.7, 0.9
workbench-22-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 68.05, 0.9
workbench-22-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 70.2, 0
workbench-23-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 66.5, 0
workbench-23-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 67.25, 0.9
workbench-23-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 67.7, 0.9
workbench-23-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 67.7, 0.9
workbench-23-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 68.05, 0.9
workbench-23-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 70.2, 0
workbench-24-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 66.5, 0
workbench-24-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 67.25, 0.9
workbench-24-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 67.7, 0.9
workbench-24-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 67.7, 0.9
workbench-24-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 68.05, 0.9
workbench-24-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 70.2, 0
cooling-unit-7Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.17, 14, 5.5
cooling-label-7CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.47.2, 15.02, 5.7
cooling-unit-23Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.123, 14, 5.5
cooling-label-23CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.423.2, 15.02, 5.7
cooling-unit-39Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.139, 14, 5.5
cooling-label-39CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.439.2, 15.02, 5.7
cooling-unit-55Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.155, 14, 5.5
cooling-label-55CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.455.2, 15.02, 5.7
wall-1Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations144 × 0.2 × 40, 0, 0
gate-1Gate (gate)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 269, 0, 0
wall-2Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations144 × 0.2 × 40, 95.8, 0
gate-2Gate (gate)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 269, 95.8, 0
wall-3Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.2 × 95.6 × 40, 0.2, 0
wall-4Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.2 × 95.6 × 4143.8, 0.2, 0
service-corridorStaff and service corridor (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationspassageassumed · Synthetic dimensions; confirm against a measured site plan.15 × 84 × 0.0264, 6, 0
lab-cell-1-1Quality work area 1 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 10, 0
workbench-1Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 12, 0
cabinet-1Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 15, 0
chair-1Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 18, 0
chair-2Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 18, 0
lab-cell-1-2Quality work area 2 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 10, 0
workbench-2Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 12, 0
cabinet-2Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 15, 0
chair-3Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 18, 0
chair-4Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 18, 0
lab-cell-1-3Quality work area 3 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 10, 0
workbench-3Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 12, 0
cabinet-3Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 15, 0
chair-5Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 18, 0
chair-6Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 18, 0
lab-cell-1-4Quality work area 4 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 10, 0
workbench-4Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 12, 0
cabinet-4Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 15, 0
chair-7Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 18, 0
chair-8Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 18, 0
lab-cell-1-5Quality work area 5 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 10, 0
workbench-5Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 12, 0
cabinet-5Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 15, 0
chair-9Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 18, 0
chair-10Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 18, 0
lab-cell-1-6Quality work area 6 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 10, 0
workbench-6Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 12, 0
cabinet-6Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 15, 0
chair-11Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 18, 0
chair-12Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 18, 0
lab-cell-2-1Quality work area 7 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 34, 0
workbench-7Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 36, 0
cabinet-7Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 39, 0
chair-13Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 42, 0
chair-14Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 42, 0
lab-cell-2-2Quality work area 8 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 34, 0
workbench-8Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 36, 0
cabinet-8Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 39, 0
chair-15Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 42, 0
chair-16Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 42, 0
lab-cell-2-3Quality work area 9 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 34, 0
workbench-9Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 36, 0
cabinet-9Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 39, 0
chair-17Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 42, 0
chair-18Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 42, 0
lab-cell-2-4Quality work area 10 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 34, 0
workbench-10Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 36, 0
cabinet-10Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 39, 0
chair-19Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 42, 0
chair-20Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 42, 0
lab-cell-2-5Quality work area 11 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 34, 0
workbench-11Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 36, 0
cabinet-11Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 39, 0
chair-21Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 42, 0
chair-22Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 42, 0
lab-cell-2-6Quality work area 12 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 34, 0
workbench-12Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 36, 0
cabinet-12Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 39, 0
chair-23Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 42, 0
chair-24Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 42, 0
lab-cell-3-1Quality work area 13 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 58, 0
workbench-13Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 60, 0
cabinet-13Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 63, 0
chair-25Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 66, 0
chair-26Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 66, 0
lab-cell-3-2Quality work area 14 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 58, 0
workbench-14Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 60, 0
cabinet-14Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 63, 0
chair-27Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 66, 0
chair-28Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 66, 0
lab-cell-3-3Quality work area 15 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 58, 0
workbench-15Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 60, 0
cabinet-15Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 63, 0
chair-29Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 66, 0
chair-30Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 66, 0
lab-cell-3-4Quality work area 16 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 58, 0
workbench-16Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 60, 0
cabinet-16Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 63, 0
chair-31Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 66, 0
chair-32Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 66, 0
lab-cell-3-5Quality work area 17 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 58, 0
workbench-17Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 60, 0
cabinet-17Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 63, 0
chair-33Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 66, 0
chair-34Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 66, 0
lab-cell-3-6Quality work area 18 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 58, 0
workbench-18Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 60, 0
cabinet-18Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 63, 0
chair-35Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 66, 0
chair-36Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 66, 0
table-1Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7484, 9.5, 0
chair-37Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 9, 0
chair-38Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 10.55, 0
chair-39Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 9, 0
chair-40Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 10.55, 0
table-2Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7491, 9.5, 0
chair-41Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 9, 0
chair-42Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 10.55, 0
chair-43Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 9, 0
chair-44Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 10.55, 0
table-3Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7498, 9.5, 0
chair-45Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 9, 0
chair-46Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 10.55, 0
chair-47Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 9, 0
chair-48Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 10.55, 0
table-4Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74105, 9.5, 0
chair-49Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 9, 0
chair-50Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 10.55, 0
chair-51Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 9, 0
chair-52Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 10.55, 0
table-5Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74112, 9.5, 0
chair-53Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 9, 0
chair-54Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 10.55, 0
chair-55Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 9, 0
chair-56Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 10.55, 0
table-6Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7484, 24.5, 0
chair-57Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 24, 0
chair-58Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 25.55, 0
chair-59Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 24, 0
chair-60Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 25.55, 0
table-7Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7491, 24.5, 0
chair-61Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 24, 0
chair-62Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 25.55, 0
chair-63Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 24, 0
chair-64Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 25.55, 0
table-8Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7498, 24.5, 0
chair-65Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 24, 0
chair-66Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 25.55, 0
chair-67Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 24, 0
chair-68Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 25.55, 0
table-9Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74105, 24.5, 0
chair-69Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 24, 0
chair-70Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 25.55, 0
chair-71Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 24, 0
chair-72Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 25.55, 0
table-10Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74112, 24.5, 0
chair-73Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 24, 0
chair-74Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 25.55, 0
chair-75Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 24, 0
chair-76Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 25.55, 0
sample-dropLaboratory sample drop (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0269, 12, 0
lab-window-7-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.67, 0, 1.25
lab-window-7-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.67, 95.8, 1.25
lab-window-23-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.623, 0, 1.25
lab-window-23-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.623, 95.8, 1.25
lab-window-39-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.639, 0, 1.25
lab-window-39-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.639, 95.8, 1.25
lab-window-55-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.655, 0, 1.25
lab-window-55-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.655, 95.8, 1.25
lab-window-85-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.685, 0, 1.25
lab-window-85-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.685, 95.8, 1.25
lab-window-101-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6101, 0, 1.25
lab-window-101-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6101, 95.8, 1.25
lab-window-117-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6117, 0, 1.25
lab-window-117-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6117, 95.8, 1.25
lab-window-133-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6133, 0, 1.25
lab-window-133-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6133, 95.8, 1.25
lab-cell-1-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 10.4, 0
lab-cell-1-1-signQUALITY LAB 01 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 10.56, 1.9
lab-cell-1-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 12.1, 0.9
lab-cell-1-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 12.1, 0.9
lab-cell-1-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 15, 0
lab-cell-1-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 18, 0
lab-cell-1-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 22, 0
lab-cell-1-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 20, 0
lab-cell-1-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 20.15, 0.9
lab-cell-1-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 20.2, 0.9
lab-cell-1-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 21, 0
lab-cell-1-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 24, 0
lab-cell-1-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 10.4, 0
lab-cell-1-2-signQUALITY LAB 02 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 10.56, 1.9
lab-cell-1-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 12.1, 0.9
lab-cell-1-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 12.1, 0.9
lab-cell-1-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 15, 0
lab-cell-1-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 18, 0
lab-cell-1-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 22, 0
lab-cell-1-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 20, 0
lab-cell-1-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 20.15, 0.9
lab-cell-1-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 20.2, 0.9
lab-cell-1-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 21, 0
lab-cell-1-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 24, 0
lab-cell-1-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 10.4, 0
lab-cell-1-3-signQUALITY LAB 03 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 10.56, 1.9
lab-cell-1-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 12.1, 0.9
lab-cell-1-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 12.1, 0.9
lab-cell-1-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 15, 0
lab-cell-1-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 18, 0
lab-cell-1-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 22, 0
lab-cell-1-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 20, 0
lab-cell-1-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 20.15, 0.9
lab-cell-1-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 20.2, 0.9
lab-cell-1-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 21, 0
lab-cell-1-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 24, 0
lab-cell-1-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 10.4, 0
lab-cell-1-4-signQUALITY LAB 04 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 10.56, 1.9
lab-cell-1-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 12.1, 0.9
lab-cell-1-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 12.1, 0.9
lab-cell-1-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 15, 0
lab-cell-1-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 18, 0
lab-cell-1-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 22, 0
lab-cell-1-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 20, 0
lab-cell-1-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 20.15, 0.9
lab-cell-1-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 20.2, 0.9
lab-cell-1-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 21, 0
lab-cell-1-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 24, 0
lab-cell-1-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 10.4, 0
lab-cell-1-5-signQUALITY LAB 05 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 10.56, 1.9
lab-cell-1-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 12.1, 0.9
lab-cell-1-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 12.1, 0.9
lab-cell-1-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 15, 0
lab-cell-1-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 18, 0
lab-cell-1-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 22, 0
lab-cell-1-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 20, 0
lab-cell-1-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 20.15, 0.9
lab-cell-1-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 20.2, 0.9
lab-cell-1-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 21, 0
lab-cell-1-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 24, 0
lab-cell-1-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 10.4, 0
lab-cell-1-6-signQUALITY LAB 06 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 10.56, 1.9
lab-cell-1-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 12.1, 0.9
lab-cell-1-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 12.1, 0.9
lab-cell-1-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 15, 0
lab-cell-1-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 18, 0
lab-cell-1-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 22, 0
lab-cell-1-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 20, 0
lab-cell-1-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 20.15, 0.9
lab-cell-1-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 20.2, 0.9
lab-cell-1-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 21, 0
lab-cell-1-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 24, 0
lab-cell-2-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 34.4, 0
lab-cell-2-1-signQUALITY LAB 07 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 34.56, 1.9
lab-cell-2-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 36.1, 0.9
lab-cell-2-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 36.1, 0.9
lab-cell-2-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 39, 0
lab-cell-2-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 42, 0
lab-cell-2-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 46, 0
lab-cell-2-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 44, 0
lab-cell-2-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 44.15, 0.9
lab-cell-2-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 44.2, 0.9
lab-cell-2-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 45, 0
lab-cell-2-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 48, 0
lab-cell-2-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 34.4, 0
lab-cell-2-2-signQUALITY LAB 08 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 34.56, 1.9
lab-cell-2-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 36.1, 0.9
lab-cell-2-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 36.1, 0.9
lab-cell-2-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 39, 0
lab-cell-2-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 42, 0
lab-cell-2-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 46, 0
lab-cell-2-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 44, 0
lab-cell-2-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 44.15, 0.9
lab-cell-2-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 44.2, 0.9
lab-cell-2-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 45, 0
lab-cell-2-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 48, 0
lab-cell-2-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 34.4, 0
lab-cell-2-3-signQUALITY LAB 09 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 34.56, 1.9
lab-cell-2-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 36.1, 0.9
lab-cell-2-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 36.1, 0.9
lab-cell-2-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 39, 0
lab-cell-2-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 42, 0
lab-cell-2-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 46, 0
lab-cell-2-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 44, 0
lab-cell-2-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 44.15, 0.9
lab-cell-2-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 44.2, 0.9
lab-cell-2-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 45, 0
lab-cell-2-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 48, 0
lab-cell-2-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 34.4, 0
lab-cell-2-4-signQUALITY LAB 10 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 34.56, 1.9
lab-cell-2-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 36.1, 0.9
lab-cell-2-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 36.1, 0.9
lab-cell-2-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 39, 0
lab-cell-2-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 42, 0
lab-cell-2-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 46, 0
lab-cell-2-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 44, 0
lab-cell-2-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 44.15, 0.9
lab-cell-2-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 44.2, 0.9
lab-cell-2-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 45, 0
lab-cell-2-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 48, 0
lab-cell-2-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 34.4, 0
lab-cell-2-5-signQUALITY LAB 11 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 34.56, 1.9
lab-cell-2-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 36.1, 0.9
lab-cell-2-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 36.1, 0.9
lab-cell-2-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 39, 0
lab-cell-2-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 42, 0
lab-cell-2-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 46, 0
lab-cell-2-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 44, 0
lab-cell-2-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 44.15, 0.9
lab-cell-2-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 44.2, 0.9
lab-cell-2-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 45, 0
lab-cell-2-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 48, 0
lab-cell-2-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 34.4, 0
lab-cell-2-6-signQUALITY LAB 12 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 34.56, 1.9
lab-cell-2-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 36.1, 0.9
lab-cell-2-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 36.1, 0.9
lab-cell-2-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 39, 0
lab-cell-2-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 42, 0
lab-cell-2-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 46, 0
lab-cell-2-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 44, 0
lab-cell-2-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 44.15, 0.9
lab-cell-2-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 44.2, 0.9
lab-cell-2-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 45, 0
lab-cell-2-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 48, 0
lab-cell-3-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 58.4, 0
lab-cell-3-1-signQUALITY LAB 13 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 58.56, 1.9
lab-cell-3-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 60.1, 0.9
lab-cell-3-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 60.1, 0.9
lab-cell-3-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 63, 0
lab-cell-3-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 66, 0
lab-cell-3-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 70, 0
lab-cell-3-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 68, 0
lab-cell-3-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 68.15, 0.9
lab-cell-3-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 68.2, 0.9
lab-cell-3-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 69, 0
lab-cell-3-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 72, 0
lab-cell-3-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 58.4, 0
lab-cell-3-2-signQUALITY LAB 14 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 58.56, 1.9
lab-cell-3-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 60.1, 0.9
lab-cell-3-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 60.1, 0.9
lab-cell-3-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 63, 0
lab-cell-3-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 66, 0
lab-cell-3-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 70, 0
lab-cell-3-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 68, 0
lab-cell-3-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 68.15, 0.9
lab-cell-3-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 68.2, 0.9
lab-cell-3-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 69, 0
lab-cell-3-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 72, 0
lab-cell-3-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 58.4, 0
lab-cell-3-3-signQUALITY LAB 15 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 58.56, 1.9
lab-cell-3-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 60.1, 0.9
lab-cell-3-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 60.1, 0.9
lab-cell-3-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 63, 0
lab-cell-3-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 66, 0
lab-cell-3-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 70, 0
lab-cell-3-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 68, 0
lab-cell-3-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 68.15, 0.9
lab-cell-3-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 68.2, 0.9
lab-cell-3-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 69, 0
lab-cell-3-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 72, 0
lab-cell-3-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 58.4, 0
lab-cell-3-4-signQUALITY LAB 16 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 58.56, 1.9
lab-cell-3-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 60.1, 0.9
lab-cell-3-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 60.1, 0.9
lab-cell-3-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 63, 0
lab-cell-3-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 66, 0
lab-cell-3-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 70, 0
lab-cell-3-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 68, 0
lab-cell-3-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 68.15, 0.9
lab-cell-3-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 68.2, 0.9
lab-cell-3-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 69, 0
lab-cell-3-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 72, 0
lab-cell-3-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 58.4, 0
lab-cell-3-5-signQUALITY LAB 17 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 58.56, 1.9
lab-cell-3-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 60.1, 0.9
lab-cell-3-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 60.1, 0.9
lab-cell-3-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 63, 0
lab-cell-3-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 66, 0
lab-cell-3-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 70, 0
lab-cell-3-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 68, 0
lab-cell-3-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 68.15, 0.9
lab-cell-3-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 68.2, 0.9
lab-cell-3-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 69, 0
lab-cell-3-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 72, 0
lab-cell-3-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 58.4, 0
lab-cell-3-6-signQUALITY LAB 18 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 58.56, 1.9
lab-cell-3-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 60.1, 0.9
lab-cell-3-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 60.1, 0.9
lab-cell-3-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 63, 0
lab-cell-3-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 66, 0
lab-cell-3-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 70, 0
lab-cell-3-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 68, 0
lab-cell-3-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 68.15, 0.9
lab-cell-3-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 68.2, 0.9
lab-cell-3-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 69, 0
lab-cell-3-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 72, 0
table-1-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5584.4, 9.6, 0.74
table-2-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5591.4, 9.6, 0.74
table-3-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5598.4, 9.6, 0.74
table-4-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55105.4, 9.6, 0.74
table-5-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55112.4, 9.6, 0.74
table-6-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5584.4, 24.6, 0.74
table-7-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5591.4, 24.6, 0.74
table-8-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5598.4, 24.6, 0.74
table-9-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55105.4, 24.6, 0.74
table-10-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55112.4, 24.6, 0.74
staff-lounge-86Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.0285, 48.5, 0
staff-sofa-86Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.986, 50, 0
staff-sofa-return-86Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.986, 54.4, 0
staff-coffee-86Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.586.8, 52.2, 0
staff-plant-86Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.190, 50, 0
staff-lounge-100Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.0299, 48.5, 0
staff-sofa-100Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9100, 50, 0
staff-sofa-return-100Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9100, 54.4, 0
staff-coffee-100Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5100.8, 52.2, 0
staff-plant-100Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1104, 50, 0
staff-lounge-114Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.02113, 48.5, 0
staff-sofa-114Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9114, 50, 0
staff-sofa-return-114Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9114, 54.4, 0
staff-coffee-114Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5114.8, 52.2, 0
staff-plant-114Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1118, 50, 0
staff-lounge-128Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.02127, 48.5, 0
staff-sofa-128Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9128, 50, 0
staff-sofa-return-128Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9128, 54.4, 0
staff-coffee-128Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5128.8, 52.2, 0
staff-plant-128Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1132, 50, 0

Model checks (0)

These checks describe the saved geometry. They do not certify access, regulations, operation or safety.

No findings from these model checks.

Alternative · Detailed · 6 carriers · 3 inspection · 4 packing slots

inputHash: fnv1a-acf97ffc · spaceHash: fnv1a-70a8a930

Saved: 2026-10-15T10:37:28.947Z

Purpose and decision

Synthetic operational planning example: Northstar Cold-chain Cross-dock

Compare the stated capacity and layout changes under identical demand.

Prepared for: Facility operations planner

Source material

IDTitle / kindReferenceNote
syntheticSynthetic operating brief (assumption)—No real site measurements, certification, demand forecast or ROI.

Provided facts, assumptions and unknowns

ItemStatusValueSourceCritical to the decision
Operating assumption 1AssumedTwo 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.synthetic—
Operating assumption 2Assumed24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.synthetic—
Operating assumption 3Assumed120 loads at 15 s intervals; two-hour observation.synthetic—
Operating assumption 4AssumedInspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.synthetic—
Operating assumption 5AssumedCarriers hold loads through all steps and return empty before becoming available.synthetic—
Operating assumption 6AssumedThe staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.synthetic—

Requirements to check

Written requirements are not automatically verified. Unknowns need confirmation before a decision.

2D drawings

Each sheet shows this saved option. The overview preserves real floors and buildings; alternatives are never drawn as additional floors.

L1 · Receiving, chilled storage and dispatch — floor plan
L1 · Receiving, chilled storage and dispatch — floor plan · NX-L1 · A3 · 1:600

inputHash: fnv1a-acf97ffc · spaceHash: fnv1a-70a8a930

L2 · Quality laboratory and staff operations — floor plan
L2 · Quality laboratory and staff operations — floor plan · NX-L2 · A3 · 1:600

inputHash: fnv1a-acf97ffc · spaceHash: fnv1a-70a8a930

3D overview

3D was not requested. The 2D drawings are included.

Quantities from the drawn model

inputHash: fnv1a-acf97ffc · spaceHash: fnv1a-70a8a930

Floor area follows the drawn outline less holes; walls are not subtracted. Overlapping floors are counted twice. These are not surveyed or legal floor areas. Dimensions are metres; areas are square metres.

FloorArea (m²)Zoned (m²)All parts
Receiving, chilled storage and dispatch (NX-L1)138242391.4445
Quality laboratory and staff operations (NX-L2)138243752410
KindCount
crate_stack106
sign96
chair76
zone75
machine64
workbench60
screen52
rack50
shelf42
platform_trolley42
cabinet36
wall26
dock_door24
person24
fridge18
washbasin18
window16
table10
sofa8
round_table4
gate4
planter4
Part inventory (855)

inputHash: fnv1a-acf97ffc · spaceHash: fnv1a-70a8a930

Includes all parts, zones and structure. The kind is a drawing primitive; tags, labels and notes identify the equipment role. CSV and JSON preserve every row.

IDLabel / kindFloor / buildingTagsSource / noteW × D × H (m)x, z, y (m)
wall-1Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations144 × 0.2 × 40, 0, 0
gate-1Gate (gate)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6 × 0.2 × 269, 0, 0
wall-2Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations144 × 0.2 × 40, 95.8, 0
gate-2Gate (gate)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6 × 0.2 × 269, 95.8, 0
wall-3Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.2 × 95.6 × 40, 0.2, 0
wall-4Wall (wall)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.2 × 95.6 × 4143.8, 0.2, 0
spineMaterial movement spine (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationspassageassumed · Synthetic dimensions; confirm against a measured site plan.12 × 88 × 0.0267, 4, 0
rack-1-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 20, 0
rack-1-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 20, 0
rack-1-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 20, 0
rack-1-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 20, 0
rack-1-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 20, 0
rack-1-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 20, 0
rack-1-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 20, 0
rack-1-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 20, 0
rack-1-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 20, 0
rack-1-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 20, 0
rack-2-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 32, 0
rack-2-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 32, 0
rack-2-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 32, 0
rack-2-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 32, 0
rack-2-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 32, 0
rack-2-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 32, 0
rack-2-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 32, 0
rack-2-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 32, 0
rack-2-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 32, 0
rack-2-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 32, 0
rack-3-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 44, 0
rack-3-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 44, 0
rack-3-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 44, 0
rack-3-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 44, 0
rack-3-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 44, 0
rack-3-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 44, 0
rack-3-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 44, 0
rack-3-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 44, 0
rack-3-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 44, 0
rack-3-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 44, 0
rack-4-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 56, 0
rack-4-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 56, 0
rack-4-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 56, 0
rack-4-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 56, 0
rack-4-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 56, 0
rack-4-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 56, 0
rack-4-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 56, 0
rack-4-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 56, 0
rack-4-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 56, 0
rack-4-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 56, 0
rack-5-1Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.55, 68, 0
rack-5-2Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.510.6, 68, 0
rack-5-3Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.516.2, 68, 0
rack-5-4Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.521.8, 68, 0
rack-5-5Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.527.4, 68, 0
rack-5-6Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.533, 68, 0
rack-5-7Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.538.6, 68, 0
rack-5-8Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.544.2, 68, 0
rack-5-9Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.549.8, 68, 0
rack-5-10Chilled rack bay (rack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsrack-bayassumed · Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.3.6 × 7 × 5.555.4, 68, 0
workbench-1Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 22, 0
shelf-1Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 22, 0
platform_trolley-1Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 25.5, 0
workbench-2Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 22, 0
shelf-2Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 22, 0
platform_trolley-2Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 25.5, 0
workbench-3Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 22, 0
shelf-3Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 22, 0
platform_trolley-3Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 25.5, 0
workbench-4Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 22, 0
shelf-4Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 22, 0
platform_trolley-4Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 25.5, 0
workbench-5Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 22, 0
shelf-5Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 22, 0
platform_trolley-5Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 25.5, 0
workbench-6Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 22, 0
shelf-6Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 22, 0
platform_trolley-6Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 25.5, 0
workbench-7Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 37, 0
shelf-7Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 37, 0
platform_trolley-7Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 40.5, 0
workbench-8Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 37, 0
shelf-8Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 37, 0
platform_trolley-8Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 40.5, 0
workbench-9Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 37, 0
shelf-9Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 37, 0
platform_trolley-9Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 40.5, 0
workbench-10Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 37, 0
shelf-10Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 37, 0
platform_trolley-10Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 40.5, 0
workbench-11Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 37, 0
shelf-11Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 37, 0
platform_trolley-11Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 40.5, 0
workbench-12Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 37, 0
shelf-12Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 37, 0
platform_trolley-12Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 40.5, 0
workbench-13Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 52, 0
shelf-13Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 52, 0
platform_trolley-13Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 55.5, 0
workbench-14Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 52, 0
shelf-14Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 52, 0
platform_trolley-14Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 55.5, 0
workbench-15Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 52, 0
shelf-15Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 52, 0
platform_trolley-15Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 55.5, 0
workbench-16Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 52, 0
shelf-16Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 52, 0
platform_trolley-16Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 55.5, 0
workbench-17Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 52, 0
shelf-17Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 52, 0
platform_trolley-17Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 55.5, 0
workbench-18Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 52, 0
shelf-18Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 52, 0
platform_trolley-18Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 55.5, 0
workbench-19Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.983, 67, 0
shelf-19Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.887.5, 67, 0
platform_trolley-19Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.983, 70.5, 0
workbench-20Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.991.5, 67, 0
shelf-20Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.896, 67, 0
platform_trolley-20Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.991.5, 70.5, 0
workbench-21Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9100, 67, 0
shelf-21Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8104.5, 67, 0
platform_trolley-21Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9100, 70.5, 0
workbench-22Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9108.5, 67, 0
shelf-22Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8113, 67, 0
platform_trolley-22Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9108.5, 70.5, 0
workbench-23Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9117, 67, 0
shelf-23Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8121.5, 67, 0
platform_trolley-23Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9117, 70.5, 0
workbench-24Packing cell (workbench)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 2 × 0.9125.5, 67, 0
shelf-24Packaging supply (shelf)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1 × 2 × 1.8130, 67, 0
platform_trolley-24Packing trolley (platform_trolley)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.1.2 × 0.8 × 0.9125.5, 70.5, 0
dock_door-1Inbound bay 1 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 47, 0, 0
dock_door-2Outbound bay 1 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 47, 95.75, 0
dock_door-3Inbound bay 2 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 417, 0, 0
dock_door-4Outbound bay 2 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 417, 95.75, 0
dock_door-5Inbound bay 3 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 427, 0, 0
dock_door-6Outbound bay 3 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 427, 95.75, 0
dock_door-7Inbound bay 4 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 437, 0, 0
dock_door-8Outbound bay 4 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 437, 95.75, 0
dock_door-9Inbound bay 5 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 447, 0, 0
dock_door-10Outbound bay 5 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 447, 95.75, 0
dock_door-11Inbound bay 6 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 457, 0, 0
dock_door-12Outbound bay 6 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 457, 95.75, 0
dock_door-13Inbound bay 7 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 467, 0, 0
dock_door-14Outbound bay 7 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 467, 95.75, 0
dock_door-15Inbound bay 8 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 477, 0, 0
dock_door-16Outbound bay 8 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 477, 95.75, 0
dock_door-17Inbound bay 9 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 487, 0, 0
dock_door-18Outbound bay 9 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 487, 95.75, 0
dock_door-19Inbound bay 10 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 497, 0, 0
dock_door-20Outbound bay 10 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 497, 95.75, 0
dock_door-21Inbound bay 11 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4107, 0, 0
dock_door-22Outbound bay 11 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4107, 95.75, 0
dock_door-23Inbound bay 12 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4117, 0, 0
dock_door-24Outbound bay 12 (dock_door)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 0.25 × 4117, 95.75, 0
receivingReceiving handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 10, 0
inspectionQuality sample handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 26, 0
cold-storeCold-store handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 45, 0
packingPacking handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 60, 0
dispatchDispatch handoff (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0272, 85, 0
mover-homeCarrier parking (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0264, 10, 0
dock_door-1-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.026.7, 3, 0
dock_door-1-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.057.3, 4.4, 0
dock_door-1-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.059.5, 4.4, 0
dock_door-1-numberIN 01 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.47.4, 0.21, 3.1
dock_door-2-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.026.7, 88, 0
dock_door-2-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.057.3, 89.4, 0
dock_door-2-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.059.5, 89.4, 0
dock_door-2-numberOUT 01 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.47.4, 95.74, 3.1
dock_door-3-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0216.7, 3, 0
dock_door-3-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0517.3, 4.4, 0
dock_door-3-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0519.5, 4.4, 0
dock_door-3-numberIN 02 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.417.4, 0.21, 3.1
dock_door-4-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0216.7, 88, 0
dock_door-4-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0517.3, 89.4, 0
dock_door-4-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0519.5, 89.4, 0
dock_door-4-numberOUT 02 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.417.4, 95.74, 3.1
dock_door-5-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0226.7, 3, 0
dock_door-5-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0527.3, 4.4, 0
dock_door-5-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0529.5, 4.4, 0
dock_door-5-numberIN 03 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.427.4, 0.21, 3.1
dock_door-6-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0226.7, 88, 0
dock_door-6-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0527.3, 89.4, 0
dock_door-6-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0529.5, 89.4, 0
dock_door-6-numberOUT 03 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.427.4, 95.74, 3.1
dock_door-7-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0236.7, 3, 0
dock_door-7-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0537.3, 4.4, 0
dock_door-7-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0539.5, 4.4, 0
dock_door-7-numberIN 04 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.437.4, 0.21, 3.1
dock_door-8-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0236.7, 88, 0
dock_door-8-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0537.3, 89.4, 0
dock_door-8-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0539.5, 89.4, 0
dock_door-8-numberOUT 04 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.437.4, 95.74, 3.1
dock_door-9-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0246.7, 3, 0
dock_door-9-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0547.3, 4.4, 0
dock_door-9-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0549.5, 4.4, 0
dock_door-9-numberIN 05 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.447.4, 0.21, 3.1
dock_door-10-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0246.7, 88, 0
dock_door-10-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0547.3, 89.4, 0
dock_door-10-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0549.5, 89.4, 0
dock_door-10-numberOUT 05 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.447.4, 95.74, 3.1
dock_door-11-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0256.7, 3, 0
dock_door-11-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0557.3, 4.4, 0
dock_door-11-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0559.5, 4.4, 0
dock_door-11-numberIN 06 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.457.4, 0.21, 3.1
dock_door-12-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0256.7, 88, 0
dock_door-12-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0557.3, 89.4, 0
dock_door-12-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0559.5, 89.4, 0
dock_door-12-numberOUT 06 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.457.4, 95.74, 3.1
dock_door-13-numberIN 07 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.467.4, 0.21, 3.1
dock_door-14-numberOUT 07 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.467.4, 95.74, 3.1
dock_door-15-numberIN 08 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.477.4, 0.21, 3.1
dock_door-16-numberOUT 08 · KEEP CLEAR (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.477.4, 95.74, 3.1
dock_door-17-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0286.7, 3, 0
dock_door-17-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0587.3, 4.4, 0
dock_door-17-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0589.5, 4.4, 0
dock_door-17-numberIN 09 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.487.4, 0.21, 3.1
dock_door-18-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0286.7, 88, 0
dock_door-18-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0587.3, 89.4, 0
dock_door-18-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0589.5, 89.4, 0
dock_door-18-numberOUT 09 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.487.4, 95.74, 3.1
dock_door-19-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0296.7, 3, 0
dock_door-19-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0597.3, 4.4, 0
dock_door-19-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0599.5, 4.4, 0
dock_door-19-numberIN 10 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.497.4, 0.21, 3.1
dock_door-20-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.0296.7, 88, 0
dock_door-20-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0597.3, 89.4, 0
dock_door-20-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.0599.5, 89.4, 0
dock_door-20-numberOUT 10 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.497.4, 95.74, 3.1
dock_door-21-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02106.7, 3, 0
dock_door-21-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05107.3, 4.4, 0
dock_door-21-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05109.5, 4.4, 0
dock_door-21-numberIN 11 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4107.4, 0.21, 3.1
dock_door-22-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02106.7, 88, 0
dock_door-22-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05107.3, 89.4, 0
dock_door-22-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05109.5, 89.4, 0
dock_door-22-numberOUT 11 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4107.4, 95.74, 3.1
dock_door-23-stagingInbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02116.7, 3, 0
dock_door-23-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05117.3, 4.4, 0
dock_door-23-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05119.5, 4.4, 0
dock_door-23-numberIN 12 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4117.4, 0.21, 3.1
dock_door-24-stagingOutbound pallet staging (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4.6 × 4.4 × 0.02116.7, 88, 0
dock_door-24-pallet-0Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05117.3, 89.4, 0
dock_door-24-pallet-1Staged temperature-controlled load (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations1.2 × 1 × 1.05119.5, 89.4, 0
dock_door-24-numberOUT 12 (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.2 × 0.04 × 0.4117.4, 95.74, 3.1
rack-1-1-numberCHILL 01 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 27.01, 1.75
rack-1-2-numberCHILL 02 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 27.01, 1.75
rack-1-3-numberCHILL 03 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 27.01, 1.75
rack-1-4-numberCHILL 04 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 27.01, 1.75
rack-1-5-numberCHILL 05 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 27.01, 1.75
rack-1-6-numberCHILL 06 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 27.01, 1.75
rack-1-7-numberCHILL 07 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 27.01, 1.75
rack-1-8-numberCHILL 08 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 27.01, 1.75
rack-1-9-numberCHILL 09 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 27.01, 1.75
rack-1-10-numberCHILL 10 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 27.01, 1.75
rack-2-1-numberCHILL 11 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 39.01, 1.75
rack-2-2-numberCHILL 12 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 39.01, 1.75
rack-2-3-numberCHILL 13 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 39.01, 1.75
rack-2-4-numberCHILL 14 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 39.01, 1.75
rack-2-5-numberCHILL 15 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 39.01, 1.75
rack-2-6-numberCHILL 16 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 39.01, 1.75
rack-2-7-numberCHILL 17 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 39.01, 1.75
rack-2-8-numberCHILL 18 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 39.01, 1.75
rack-2-9-numberCHILL 19 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 39.01, 1.75
rack-2-10-numberCHILL 20 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 39.01, 1.75
rack-3-1-numberCHILL 21 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 51.01, 1.75
rack-3-2-numberCHILL 22 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 51.01, 1.75
rack-3-3-numberCHILL 23 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 51.01, 1.75
rack-3-4-numberCHILL 24 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 51.01, 1.75
rack-3-5-numberCHILL 25 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 51.01, 1.75
rack-3-6-numberCHILL 26 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 51.01, 1.75
rack-3-7-numberCHILL 27 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 51.01, 1.75
rack-3-8-numberCHILL 28 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 51.01, 1.75
rack-3-9-numberCHILL 29 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 51.01, 1.75
rack-3-10-numberCHILL 30 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 51.01, 1.75
rack-4-1-numberCHILL 31 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 63.01, 1.75
rack-4-2-numberCHILL 32 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 63.01, 1.75
rack-4-3-numberCHILL 33 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 63.01, 1.75
rack-4-4-numberCHILL 34 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 63.01, 1.75
rack-4-5-numberCHILL 35 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 63.01, 1.75
rack-4-6-numberCHILL 36 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 63.01, 1.75
rack-4-7-numberCHILL 37 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 63.01, 1.75
rack-4-8-numberCHILL 38 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 63.01, 1.75
rack-4-9-numberCHILL 39 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 63.01, 1.75
rack-4-10-numberCHILL 40 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 63.01, 1.75
rack-5-1-numberCHILL 41 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.45.3, 75.01, 1.75
rack-5-2-numberCHILL 42 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.410.9, 75.01, 1.75
rack-5-3-numberCHILL 43 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.416.5, 75.01, 1.75
rack-5-4-numberCHILL 44 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.422.1, 75.01, 1.75
rack-5-5-numberCHILL 45 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.427.7, 75.01, 1.75
rack-5-6-numberCHILL 46 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.433.3, 75.01, 1.75
rack-5-7-numberCHILL 47 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.438.9, 75.01, 1.75
rack-5-8-numberCHILL 48 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.444.5, 75.01, 1.75
rack-5-9-numberCHILL 49 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.450.099999999999994, 75.01, 1.75
rack-5-10-numberCHILL 50 · 6 POSITIONS (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3 × 0.04 × 0.455.699999999999996, 75.01, 1.75
workbench-1-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 21.5, 0
workbench-1-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 22.25, 0.9
workbench-1-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 22.7, 0.9
workbench-1-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 22.7, 0.9
workbench-1-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 23.05, 0.9
workbench-1-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 25.2, 0
workbench-2-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 21.5, 0
workbench-2-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 22.25, 0.9
workbench-2-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 22.7, 0.9
workbench-2-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 22.7, 0.9
workbench-2-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 23.05, 0.9
workbench-2-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 25.2, 0
workbench-3-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 21.5, 0
workbench-3-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 22.25, 0.9
workbench-3-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 22.7, 0.9
workbench-3-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 22.7, 0.9
workbench-3-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 23.05, 0.9
workbench-3-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 25.2, 0
workbench-4-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 21.5, 0
workbench-4-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 22.25, 0.9
workbench-4-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 22.7, 0.9
workbench-4-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 22.7, 0.9
workbench-4-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 23.05, 0.9
workbench-4-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 25.2, 0
workbench-5-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 21.5, 0
workbench-5-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 22.25, 0.9
workbench-5-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 22.7, 0.9
workbench-5-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 22.7, 0.9
workbench-5-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 23.05, 0.9
workbench-5-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 25.2, 0
workbench-6-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 21.5, 0
workbench-6-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 22.25, 0.9
workbench-6-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 22.7, 0.9
workbench-6-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 22.7, 0.9
workbench-6-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 23.05, 0.9
workbench-6-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 25.2, 0
workbench-7-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 36.5, 0
workbench-7-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 37.25, 0.9
workbench-7-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 37.7, 0.9
workbench-7-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 37.7, 0.9
workbench-7-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 38.05, 0.9
workbench-7-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 40.2, 0
workbench-8-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 36.5, 0
workbench-8-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 37.25, 0.9
workbench-8-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 37.7, 0.9
workbench-8-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 37.7, 0.9
workbench-8-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 38.05, 0.9
workbench-8-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 40.2, 0
workbench-9-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 36.5, 0
workbench-9-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 37.25, 0.9
workbench-9-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 37.7, 0.9
workbench-9-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 37.7, 0.9
workbench-9-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 38.05, 0.9
workbench-9-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 40.2, 0
workbench-10-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 36.5, 0
workbench-10-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 37.25, 0.9
workbench-10-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 37.7, 0.9
workbench-10-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 37.7, 0.9
workbench-10-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 38.05, 0.9
workbench-10-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 40.2, 0
workbench-11-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 36.5, 0
workbench-11-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 37.25, 0.9
workbench-11-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 37.7, 0.9
workbench-11-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 37.7, 0.9
workbench-11-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 38.05, 0.9
workbench-11-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 40.2, 0
workbench-12-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 36.5, 0
workbench-12-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 37.25, 0.9
workbench-12-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 37.7, 0.9
workbench-12-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 37.7, 0.9
workbench-12-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 38.05, 0.9
workbench-12-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 40.2, 0
workbench-13-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 51.5, 0
workbench-13-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 52.25, 0.9
workbench-13-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 52.7, 0.9
workbench-13-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 52.7, 0.9
workbench-13-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 53.05, 0.9
workbench-13-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 55.2, 0
workbench-14-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 51.5, 0
workbench-14-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 52.25, 0.9
workbench-14-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 52.7, 0.9
workbench-14-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 52.7, 0.9
workbench-14-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 53.05, 0.9
workbench-14-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 55.2, 0
workbench-15-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 51.5, 0
workbench-15-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 52.25, 0.9
workbench-15-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 52.7, 0.9
workbench-15-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 52.7, 0.9
workbench-15-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 53.05, 0.9
workbench-15-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 55.2, 0
workbench-16-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 51.5, 0
workbench-16-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 52.25, 0.9
workbench-16-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 52.7, 0.9
workbench-16-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 52.7, 0.9
workbench-16-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 53.05, 0.9
workbench-16-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 55.2, 0
workbench-17-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 51.5, 0
workbench-17-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 52.25, 0.9
workbench-17-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 52.7, 0.9
workbench-17-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 52.7, 0.9
workbench-17-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 53.05, 0.9
workbench-17-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 55.2, 0
workbench-18-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 51.5, 0
workbench-18-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 52.25, 0.9
workbench-18-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 52.7, 0.9
workbench-18-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 52.7, 0.9
workbench-18-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 53.05, 0.9
workbench-18-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 55.2, 0
workbench-19-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0282.6, 66.5, 0
workbench-19-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.585.5, 67.25, 0.9
workbench-19-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3583.3, 67.7, 0.9
workbench-19-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5584.3, 67.7, 0.9
workbench-19-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.385.6, 68.05, 0.9
workbench-19-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.785, 70.2, 0
workbench-20-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0291.1, 66.5, 0
workbench-20-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.594, 67.25, 0.9
workbench-20-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.3591.8, 67.7, 0.9
workbench-20-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.5592.8, 67.7, 0.9
workbench-20-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.394.1, 68.05, 0.9
workbench-20-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.793.5, 70.2, 0
workbench-21-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.0299.6, 66.5, 0
workbench-21-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5102.5, 67.25, 0.9
workbench-21-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35100.3, 67.7, 0.9
workbench-21-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55101.3, 67.7, 0.9
workbench-21-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3102.6, 68.05, 0.9
workbench-21-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7102, 70.2, 0
workbench-22-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02108.1, 66.5, 0
workbench-22-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5111, 67.25, 0.9
workbench-22-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35108.8, 67.7, 0.9
workbench-22-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55109.8, 67.7, 0.9
workbench-22-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3111.1, 68.05, 0.9
workbench-22-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7110.5, 70.2, 0
workbench-23-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02116.6, 66.5, 0
workbench-23-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5119.5, 67.25, 0.9
workbench-23-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35117.3, 67.7, 0.9
workbench-23-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55118.3, 67.7, 0.9
workbench-23-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3119.6, 68.05, 0.9
workbench-23-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7119, 70.2, 0
workbench-24-stationPacking work area (zone)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations6.4 × 6 × 0.02125.1, 66.5, 0
workbench-24-terminalPacking order terminal (screen)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.8 × 0.2 × 0.5128, 67.25, 0.9
workbench-24-carton-0Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.35125.8, 67.7, 0.9
workbench-24-carton-1Cartons on packing bench (crate_stack)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.7 × 0.7 × 0.55126.8, 67.7, 0.9
workbench-24-scannerBench scale and label printer (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.65 × 0.55 × 0.3128.1, 68.05, 0.9
workbench-24-operatorPacking operator (person)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations0.45 × 0.45 × 1.7127.5, 70.2, 0
cooling-unit-7Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.17, 14, 5.5
cooling-label-7CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.47.2, 15.02, 5.7
cooling-unit-23Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.123, 14, 5.5
cooling-label-23CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.423.2, 15.02, 5.7
cooling-unit-39Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.139, 14, 5.5
cooling-label-39CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.439.2, 15.02, 5.7
cooling-unit-55Cold-store evaporator (machine)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations4 × 1 × 1.155, 14, 5.5
cooling-label-55CHILLED STORAGE (sign)Receiving, chilled storage and dispatch (NX-L1) / Cross-dock and quality operations3.6 × 0.04 × 0.455.2, 15.02, 5.7
wall-1Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations144 × 0.2 × 40, 0, 0
gate-1Gate (gate)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 269, 0, 0
wall-2Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations144 × 0.2 × 40, 95.8, 0
gate-2Gate (gate)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 269, 95.8, 0
wall-3Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.2 × 95.6 × 40, 0.2, 0
wall-4Wall (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.2 × 95.6 × 4143.8, 0.2, 0
service-corridorStaff and service corridor (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationspassageassumed · Synthetic dimensions; confirm against a measured site plan.15 × 84 × 0.0264, 6, 0
lab-cell-1-1Quality work area 1 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 10, 0
workbench-1Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 12, 0
cabinet-1Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 15, 0
chair-1Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 18, 0
chair-2Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 18, 0
lab-cell-1-2Quality work area 2 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 10, 0
workbench-2Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 12, 0
cabinet-2Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 15, 0
chair-3Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 18, 0
chair-4Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 18, 0
lab-cell-1-3Quality work area 3 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 10, 0
workbench-3Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 12, 0
cabinet-3Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 15, 0
chair-5Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 18, 0
chair-6Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 18, 0
lab-cell-1-4Quality work area 4 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 10, 0
workbench-4Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 12, 0
cabinet-4Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 15, 0
chair-7Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 18, 0
chair-8Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 18, 0
lab-cell-1-5Quality work area 5 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 10, 0
workbench-5Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 12, 0
cabinet-5Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 15, 0
chair-9Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 18, 0
chair-10Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 18, 0
lab-cell-1-6Quality work area 6 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 10, 0
workbench-6Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 12, 0
cabinet-6Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 15, 0
chair-11Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 18, 0
chair-12Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 18, 0
lab-cell-2-1Quality work area 7 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 34, 0
workbench-7Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 36, 0
cabinet-7Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 39, 0
chair-13Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 42, 0
chair-14Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 42, 0
lab-cell-2-2Quality work area 8 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 34, 0
workbench-8Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 36, 0
cabinet-8Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 39, 0
chair-15Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 42, 0
chair-16Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 42, 0
lab-cell-2-3Quality work area 9 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 34, 0
workbench-9Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 36, 0
cabinet-9Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 39, 0
chair-17Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 42, 0
chair-18Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 42, 0
lab-cell-2-4Quality work area 10 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 34, 0
workbench-10Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 36, 0
cabinet-10Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 39, 0
chair-19Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 42, 0
chair-20Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 42, 0
lab-cell-2-5Quality work area 11 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 34, 0
workbench-11Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 36, 0
cabinet-11Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 39, 0
chair-21Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 42, 0
chair-22Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 42, 0
lab-cell-2-6Quality work area 12 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 34, 0
workbench-12Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 36, 0
cabinet-12Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 39, 0
chair-23Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 42, 0
chair-24Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 42, 0
lab-cell-3-1Quality work area 13 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.025, 58, 0
workbench-13Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.96, 60, 0
cabinet-13Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.86, 63, 0
chair-25Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.856, 66, 0
chair-26Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.858, 66, 0
lab-cell-3-2Quality work area 14 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0214, 58, 0
workbench-14Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.915, 60, 0
cabinet-14Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.815, 63, 0
chair-27Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8515, 66, 0
chair-28Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8517, 66, 0
lab-cell-3-3Quality work area 15 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0223, 58, 0
workbench-15Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.924, 60, 0
cabinet-15Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.824, 63, 0
chair-29Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8524, 66, 0
chair-30Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8526, 66, 0
lab-cell-3-4Quality work area 16 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0232, 58, 0
workbench-16Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.933, 60, 0
cabinet-16Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.833, 63, 0
chair-31Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8533, 66, 0
chair-32Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8535, 66, 0
lab-cell-3-5Quality work area 17 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0241, 58, 0
workbench-17Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.942, 60, 0
cabinet-17Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.842, 63, 0
chair-33Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8542, 66, 0
chair-34Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8544, 66, 0
lab-cell-3-6Quality work area 18 (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.7 × 18 × 0.0250, 58, 0
workbench-18Laboratory workbench (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.4 × 1 × 0.951, 60, 0
cabinet-18Sample cabinet (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.2 × 1 × 1.851, 63, 0
chair-35Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8551, 66, 0
chair-36Laboratory chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.0.5 × 0.5 × 0.8553, 66, 0
table-1Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7484, 9.5, 0
chair-37Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 9, 0
chair-38Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 10.55, 0
chair-39Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 9, 0
chair-40Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 10.55, 0
table-2Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7491, 9.5, 0
chair-41Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 9, 0
chair-42Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 10.55, 0
chair-43Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 9, 0
chair-44Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 10.55, 0
table-3Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7498, 9.5, 0
chair-45Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 9, 0
chair-46Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 10.55, 0
chair-47Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 9, 0
chair-48Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 10.55, 0
table-4Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74105, 9.5, 0
chair-49Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 9, 0
chair-50Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 10.55, 0
chair-51Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 9, 0
chair-52Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 10.55, 0
table-5Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74112, 9.5, 0
chair-53Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 9, 0
chair-54Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 10.55, 0
chair-55Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 9, 0
chair-56Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 10.55, 0
table-6Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7484, 24.5, 0
chair-57Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 24, 0
chair-58Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8584.275, 25.55, 0
chair-59Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 24, 0
chair-60Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8585.275, 25.55, 0
table-7Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7491, 24.5, 0
chair-61Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 24, 0
chair-62Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8591.275, 25.55, 0
chair-63Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 24, 0
chair-64Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8592.275, 25.55, 0
table-8Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.7498, 24.5, 0
chair-65Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 24, 0
chair-66Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8598.275, 25.55, 0
chair-67Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 24, 0
chair-68Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.8599.275, 25.55, 0
table-9Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74105, 24.5, 0
chair-69Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 24, 0
chair-70Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85105.275, 25.55, 0
chair-71Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 24, 0
chair-72Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85106.275, 25.55, 0
table-10Staff collaboration table (table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2 × 1 × 0.74112, 24.5, 0
chair-73Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 24, 0
chair-74Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85112.275, 25.55, 0
chair-75Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 24, 0
chair-76Chair (chair)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.45 × 0.45 × 0.85113.275, 25.55, 0
sample-dropLaboratory sample drop (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operationsassumed · Synthetic dimensions; confirm against a measured site plan.3 × 3 × 0.0269, 12, 0
lab-window-7-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.67, 0, 1.25
lab-window-7-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.67, 95.8, 1.25
lab-window-23-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.623, 0, 1.25
lab-window-23-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.623, 95.8, 1.25
lab-window-39-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.639, 0, 1.25
lab-window-39-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.639, 95.8, 1.25
lab-window-55-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.655, 0, 1.25
lab-window-55-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.655, 95.8, 1.25
lab-window-85-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.685, 0, 1.25
lab-window-85-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.685, 95.8, 1.25
lab-window-101-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6101, 0, 1.25
lab-window-101-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6101, 95.8, 1.25
lab-window-117-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6117, 0, 1.25
lab-window-117-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6117, 95.8, 1.25
lab-window-133-0Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6133, 0, 1.25
lab-window-133-95.8Laboratory clerestory (window)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6 × 0.2 × 1.6133, 95.8, 1.25
lab-cell-1-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 10.4, 0
lab-cell-1-1-signQUALITY LAB 01 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 10.56, 1.9
lab-cell-1-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 12.1, 0.9
lab-cell-1-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 12.1, 0.9
lab-cell-1-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 15, 0
lab-cell-1-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 18, 0
lab-cell-1-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 22, 0
lab-cell-1-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 20, 0
lab-cell-1-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 20.15, 0.9
lab-cell-1-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 20.2, 0.9
lab-cell-1-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 21, 0
lab-cell-1-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 24, 0
lab-cell-1-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 10.4, 0
lab-cell-1-2-signQUALITY LAB 02 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 10.56, 1.9
lab-cell-1-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 12.1, 0.9
lab-cell-1-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 12.1, 0.9
lab-cell-1-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 15, 0
lab-cell-1-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 18, 0
lab-cell-1-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 22, 0
lab-cell-1-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 20, 0
lab-cell-1-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 20.15, 0.9
lab-cell-1-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 20.2, 0.9
lab-cell-1-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 21, 0
lab-cell-1-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 24, 0
lab-cell-1-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 10.4, 0
lab-cell-1-3-signQUALITY LAB 03 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 10.56, 1.9
lab-cell-1-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 12.1, 0.9
lab-cell-1-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 12.1, 0.9
lab-cell-1-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 15, 0
lab-cell-1-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 18, 0
lab-cell-1-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 22, 0
lab-cell-1-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 20, 0
lab-cell-1-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 20.15, 0.9
lab-cell-1-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 20.2, 0.9
lab-cell-1-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 21, 0
lab-cell-1-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 24, 0
lab-cell-1-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 10.4, 0
lab-cell-1-4-signQUALITY LAB 04 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 10.56, 1.9
lab-cell-1-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 12.1, 0.9
lab-cell-1-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 12.1, 0.9
lab-cell-1-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 15, 0
lab-cell-1-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 18, 0
lab-cell-1-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 22, 0
lab-cell-1-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 20, 0
lab-cell-1-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 20.15, 0.9
lab-cell-1-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 20.2, 0.9
lab-cell-1-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 21, 0
lab-cell-1-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 24, 0
lab-cell-1-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 10.4, 0
lab-cell-1-5-signQUALITY LAB 05 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 10.56, 1.9
lab-cell-1-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 12.1, 0.9
lab-cell-1-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 12.1, 0.9
lab-cell-1-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 15, 0
lab-cell-1-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 18, 0
lab-cell-1-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 22, 0
lab-cell-1-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 20, 0
lab-cell-1-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 20.15, 0.9
lab-cell-1-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 20.2, 0.9
lab-cell-1-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 21, 0
lab-cell-1-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 24, 0
lab-cell-1-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 10.4, 0
lab-cell-1-6-signQUALITY LAB 06 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 10.56, 1.9
lab-cell-1-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 12.1, 0.9
lab-cell-1-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 12.1, 0.9
lab-cell-1-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 15, 0
lab-cell-1-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 18, 0
lab-cell-1-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 22, 0
lab-cell-1-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 20, 0
lab-cell-1-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 20.15, 0.9
lab-cell-1-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 20.2, 0.9
lab-cell-1-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 21, 0
lab-cell-1-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 24, 0
lab-cell-2-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 34.4, 0
lab-cell-2-1-signQUALITY LAB 07 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 34.56, 1.9
lab-cell-2-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 36.1, 0.9
lab-cell-2-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 36.1, 0.9
lab-cell-2-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 39, 0
lab-cell-2-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 42, 0
lab-cell-2-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 46, 0
lab-cell-2-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 44, 0
lab-cell-2-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 44.15, 0.9
lab-cell-2-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 44.2, 0.9
lab-cell-2-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 45, 0
lab-cell-2-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 48, 0
lab-cell-2-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 34.4, 0
lab-cell-2-2-signQUALITY LAB 08 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 34.56, 1.9
lab-cell-2-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 36.1, 0.9
lab-cell-2-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 36.1, 0.9
lab-cell-2-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 39, 0
lab-cell-2-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 42, 0
lab-cell-2-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 46, 0
lab-cell-2-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 44, 0
lab-cell-2-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 44.15, 0.9
lab-cell-2-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 44.2, 0.9
lab-cell-2-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 45, 0
lab-cell-2-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 48, 0
lab-cell-2-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 34.4, 0
lab-cell-2-3-signQUALITY LAB 09 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 34.56, 1.9
lab-cell-2-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 36.1, 0.9
lab-cell-2-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 36.1, 0.9
lab-cell-2-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 39, 0
lab-cell-2-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 42, 0
lab-cell-2-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 46, 0
lab-cell-2-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 44, 0
lab-cell-2-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 44.15, 0.9
lab-cell-2-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 44.2, 0.9
lab-cell-2-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 45, 0
lab-cell-2-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 48, 0
lab-cell-2-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 34.4, 0
lab-cell-2-4-signQUALITY LAB 10 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 34.56, 1.9
lab-cell-2-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 36.1, 0.9
lab-cell-2-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 36.1, 0.9
lab-cell-2-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 39, 0
lab-cell-2-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 42, 0
lab-cell-2-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 46, 0
lab-cell-2-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 44, 0
lab-cell-2-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 44.15, 0.9
lab-cell-2-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 44.2, 0.9
lab-cell-2-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 45, 0
lab-cell-2-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 48, 0
lab-cell-2-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 34.4, 0
lab-cell-2-5-signQUALITY LAB 11 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 34.56, 1.9
lab-cell-2-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 36.1, 0.9
lab-cell-2-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 36.1, 0.9
lab-cell-2-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 39, 0
lab-cell-2-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 42, 0
lab-cell-2-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 46, 0
lab-cell-2-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 44, 0
lab-cell-2-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 44.15, 0.9
lab-cell-2-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 44.2, 0.9
lab-cell-2-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 45, 0
lab-cell-2-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 48, 0
lab-cell-2-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 34.4, 0
lab-cell-2-6-signQUALITY LAB 12 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 34.56, 1.9
lab-cell-2-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 36.1, 0.9
lab-cell-2-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 36.1, 0.9
lab-cell-2-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 39, 0
lab-cell-2-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 42, 0
lab-cell-2-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 46, 0
lab-cell-2-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 44, 0
lab-cell-2-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 44.15, 0.9
lab-cell-2-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 44.2, 0.9
lab-cell-2-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 45, 0
lab-cell-2-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 48, 0
lab-cell-3-1-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.55.4, 58.4, 0
lab-cell-3-1-signQUALITY LAB 13 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.45.8, 58.56, 1.9
lab-cell-3-1-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.68.8, 60.1, 0.9
lab-cell-3-1-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.76.25, 60.1, 0.9
lab-cell-3-1-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.99.8, 63, 0
lab-cell-3-1-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.99.8, 66, 0
lab-cell-3-1-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.96, 70, 0
lab-cell-3-1-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.96, 68, 0
lab-cell-3-1-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.456.15, 68.15, 0.9
lab-cell-3-1-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.357.3, 68.2, 0.9
lab-cell-3-1-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.89.8, 69, 0
lab-cell-3-1-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.26, 72, 0
lab-cell-3-2-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.514.4, 58.4, 0
lab-cell-3-2-signQUALITY LAB 14 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.414.8, 58.56, 1.9
lab-cell-3-2-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.617.8, 60.1, 0.9
lab-cell-3-2-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.715.25, 60.1, 0.9
lab-cell-3-2-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.918.8, 63, 0
lab-cell-3-2-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.918.8, 66, 0
lab-cell-3-2-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.915, 70, 0
lab-cell-3-2-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.915, 68, 0
lab-cell-3-2-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4515.15, 68.15, 0.9
lab-cell-3-2-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3516.3, 68.2, 0.9
lab-cell-3-2-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.818.8, 69, 0
lab-cell-3-2-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.215, 72, 0
lab-cell-3-3-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.523.4, 58.4, 0
lab-cell-3-3-signQUALITY LAB 15 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.423.8, 58.56, 1.9
lab-cell-3-3-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.626.8, 60.1, 0.9
lab-cell-3-3-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.724.25, 60.1, 0.9
lab-cell-3-3-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.927.8, 63, 0
lab-cell-3-3-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.927.8, 66, 0
lab-cell-3-3-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.924, 70, 0
lab-cell-3-3-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.924, 68, 0
lab-cell-3-3-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4524.15, 68.15, 0.9
lab-cell-3-3-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3525.3, 68.2, 0.9
lab-cell-3-3-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.827.8, 69, 0
lab-cell-3-3-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.224, 72, 0
lab-cell-3-4-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.532.4, 58.4, 0
lab-cell-3-4-signQUALITY LAB 16 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.432.8, 58.56, 1.9
lab-cell-3-4-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.635.8, 60.1, 0.9
lab-cell-3-4-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.733.25, 60.1, 0.9
lab-cell-3-4-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.936.8, 63, 0
lab-cell-3-4-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.936.8, 66, 0
lab-cell-3-4-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.933, 70, 0
lab-cell-3-4-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.933, 68, 0
lab-cell-3-4-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4533.15, 68.15, 0.9
lab-cell-3-4-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3534.3, 68.2, 0.9
lab-cell-3-4-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.836.8, 69, 0
lab-cell-3-4-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.233, 72, 0
lab-cell-3-5-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.541.4, 58.4, 0
lab-cell-3-5-signQUALITY LAB 17 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.441.8, 58.56, 1.9
lab-cell-3-5-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.644.8, 60.1, 0.9
lab-cell-3-5-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.742.25, 60.1, 0.9
lab-cell-3-5-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.945.8, 63, 0
lab-cell-3-5-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.945.8, 66, 0
lab-cell-3-5-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.942, 70, 0
lab-cell-3-5-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.942, 68, 0
lab-cell-3-5-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4542.15, 68.15, 0.9
lab-cell-3-5-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3543.3, 68.2, 0.9
lab-cell-3-5-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.845.8, 69, 0
lab-cell-3-5-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.242, 72, 0
lab-cell-3-6-backLaboratory service panel (wall)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations6.2 × 0.15 × 2.550.4, 58.4, 0
lab-cell-3-6-signQUALITY LAB 18 (sign)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations5.4 × 0.04 × 0.450.8, 58.56, 1.9
lab-cell-3-6-terminalSample analysis display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.15 × 0.653.8, 60.1, 0.9
lab-cell-3-6-analyserBench sample analyser (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.751.25, 60.1, 0.9
lab-cell-3-6-fridgeRetained sample refrigerator (fridge)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.8 × 1.954.8, 63, 0
lab-cell-3-6-basinLaboratory handwash basin (washbasin)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.7 × 0.954.8, 66, 0
lab-cell-3-6-cartSample transport cart (platform_trolley)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1 × 0.7 × 0.951, 70, 0
lab-cell-3-6-prep-benchSample preparation island (workbench)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 0.951, 68, 0
lab-cell-3-6-prep-scaleSample weighing station (machine)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.6 × 0.4551.15, 68.15, 0.9
lab-cell-3-6-sample-traysSample trays on preparation bench (crate_stack)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.9 × 0.6 × 0.3552.3, 68.2, 0.9
lab-cell-3-6-retained-samplesRetained sample shelving (shelf)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 4.8 × 1.854.8, 69, 0
lab-cell-3-6-recordsSample records and consumables (cabinet)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations2.6 × 1 × 1.251, 72, 0
table-1-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5584.4, 9.6, 0.74
table-2-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5591.4, 9.6, 0.74
table-3-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5598.4, 9.6, 0.74
table-4-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55105.4, 9.6, 0.74
table-5-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55112.4, 9.6, 0.74
table-6-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5584.4, 24.6, 0.74
table-7-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5591.4, 24.6, 0.74
table-8-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.5598.4, 24.6, 0.74
table-9-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55105.4, 24.6, 0.74
table-10-screenOperations desk display (screen)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 0.18 × 0.55112.4, 24.6, 0.74
staff-lounge-86Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.0285, 48.5, 0
staff-sofa-86Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.986, 50, 0
staff-sofa-return-86Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.986, 54.4, 0
staff-coffee-86Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.586.8, 52.2, 0
staff-plant-86Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.190, 50, 0
staff-lounge-100Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.0299, 48.5, 0
staff-sofa-100Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9100, 50, 0
staff-sofa-return-100Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9100, 54.4, 0
staff-coffee-100Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5100.8, 52.2, 0
staff-plant-100Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1104, 50, 0
staff-lounge-114Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.02113, 48.5, 0
staff-sofa-114Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9114, 50, 0
staff-sofa-return-114Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9114, 54.4, 0
staff-coffee-114Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5114.8, 52.2, 0
staff-plant-114Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1118, 50, 0
staff-lounge-128Staff break area (zone)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations7 × 8 × 0.02127, 48.5, 0
staff-sofa-128Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9128, 50, 0
staff-sofa-return-128Staff break seating (sofa)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations3 × 0.95 × 0.9128, 54.4, 0
staff-coffee-128Break table (round_table)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations1.1 × 1.1 × 0.5128.8, 52.2, 0
staff-plant-128Staff lounge planting (planter)Quality laboratory and staff operations (NX-L2) / Cross-dock and quality operations0.8 × 0.8 × 1.1132, 50, 0

Model checks (0)

These checks describe the saved geometry. They do not certify access, regulations, operation or safety.

No findings from these model checks.

Detailed · 3 carriers · 2 inspection · 2 packing slots → Detailed · 6 carriers · 3 inspection · 4 packing slots

fnv1a-b24498c7 → fnv1a-acf97ffc

Changes by stable ID

The same floor and ID identify a part. A cross-floor move is recognized only when that ID occurs once in each complete option. No matching by name or nearby position.

IDChangeFromToFields
packingMovedPacking handoff / Receiving, chilled storage and dispatch (NX-L1)Packing handoff / Receiving, chilled storage and dispatch (NX-L1)z: 65 → 60

Floor, building and connection changes

TypeIDChangeFields

Baseline fixed conditions

No fixed parts were recorded in the baseline.

Fixed floor frames: —
Fixed connections: —

Complete structured data
{"version":1,"title":"Northstar Cold-chain Cross-dock — detailed capacity study","locale":"en","baselineId":"northstar-detail-layout-a","drawingAndInventoryFloors":["NX-L1","NX-L2"],"options":[{"id":"northstar-detail-layout-a","name":"Detailed · 3 carriers · 2 inspection · 2 packing slots","createdAt":"2026-10-15T10:37:26.695Z","inputHash":"fnv1a-b24498c7","spaceHash":"fnv1a-fc82ac11","brief":{"purpose":"Synthetic operational planning example: Northstar Cold-chain Cross-dock","decision":"Compare the stated capacity and layout changes under identical demand.","preparedFor":"Facility operations planner","sources":[{"id":"synthetic","title":"Synthetic operating brief","kind":"assumption","note":"No real site measurements, certification, demand forecast or ROI."}],"facts":[{"id":"assumption-1","label":"Operating assumption 1","value":"Two 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-2","label":"Operating assumption 2","value":"24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-3","label":"Operating assumption 3","value":"120 loads at 15 s intervals; two-hour observation.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-4","label":"Operating assumption 4","value":"Inspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-5","label":"Operating assumption 5","value":"Carriers hold loads through all steps and return empty before becoming available.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-6","label":"Operating assumption 6","value":"The staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.","status":"assumed","sourceId":"synthetic","decisionCritical":false}],"requirements":["Preserve the synthetic dimensions and declared demand.","Check real clearances, service times and demand before any operational use."],"fixedParts":[]},"underlays":[],"quantities":{"units":{"length":"m","area":"m²"},"site":{"floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4,"parts":855},"levels":[{"level":0,"label":"L1","floors":["NX-L1"],"floorAreaSquareMetres":13824,"zonedSquareMetres":2391.4},{"level":1,"label":"L2","floors":["NX-L2"],"floorAreaSquareMetres":13824,"zonedSquareMetres":3752}],"structures":[{"id":"NX","name":"Cross-dock and quality operations","floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4}],"uses":[{"use":"facility","name":"Facility / retail","floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4}],"floors":[{"id":"NX-L1","name":"Receiving, chilled storage and dispatch","level":0,"label":"L1","structure":"NX","use":"facility","floorAreaSquareMetres":13824,"zonedSquareMetres":2391.4,"unzonedSquareMetres":11432.6,"zoneOverlapSquareMetres":45,"zones":[{"id":"spine","label":"Material movement spine","tags":["passage"],"areaSquareMetres":1056,"overlaps":[{"id":"receiving","squareMetres":9},{"id":"inspection","squareMetres":9},{"id":"cold-store","squareMetres":9},{"id":"packing","squareMetres":9},{"id":"dispatch","squareMetres":9}]},{"id":"receiving","label":"Receiving handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"inspection","label":"Quality sample handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"cold-store","label":"Cold-store handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"packing","label":"Packing handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"dispatch","label":"Dispatch handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"mover-home","label":"Carrier parking","areaSquareMetres":9},{"id":"dock_door-1-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-2-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-3-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-4-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-5-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-6-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-7-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-8-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-9-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-10-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-11-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-12-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-17-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-18-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-19-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-20-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-21-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-22-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-23-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-24-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"workbench-1-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-2-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-3-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-4-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-5-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-6-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-7-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-8-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-9-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-10-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-11-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-12-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-13-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-14-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-15-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-16-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-17-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-18-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-19-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-20-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-21-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-22-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-23-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-24-station","label":"Packing work area","areaSquareMetres":38.4}],"tags":[{"tag":"passage","zones":1,"areaSquareMetres":1056}],"markings":[],"parts":[{"kind":"crate_stack","name":"Stack of crates","count":88},{"kind":"sign","name":"Sign","count":78},{"kind":"zone","name":"Floor zone","count":51},{"kind":"rack","name":"Pallet rack","count":50},{"kind":"machine","name":"Machine","count":28},{"kind":"shelf","name":"Shelf","count":24},{"kind":"workbench","name":"Workbench","count":24},{"kind":"dock_door","name":"Loading dock door","count":24},{"kind":"screen","name":"Screen","count":24},{"kind":"person","name":"Person (standing)","count":24},{"kind":"platform_trolley","name":"Platform trolley","count":24},{"kind":"wall","name":"Wall","count":4,"lengthMetres":479.2},{"kind":"gate","name":"Gate","count":2}],"partCount":445},{"id":"NX-L2","name":"Quality laboratory and staff operations","level":1,"label":"L2","structure":"NX","use":"facility","floorAreaSquareMetres":13824,"zonedSquareMetres":3752,"unzonedSquareMetres":10072,"zoneOverlapSquareMetres":9,"zones":[{"id":"service-corridor","label":"Staff and service corridor","tags":["passage"],"areaSquareMetres":1260,"overlaps":[{"id":"sample-drop","squareMetres":9}]},{"id":"lab-cell-1-1","label":"Quality work area 1","areaSquareMetres":126},{"id":"lab-cell-1-2","label":"Quality work area 2","areaSquareMetres":126},{"id":"lab-cell-1-3","label":"Quality work area 3","areaSquareMetres":126},{"id":"lab-cell-1-4","label":"Quality work area 4","areaSquareMetres":126},{"id":"lab-cell-1-5","label":"Quality work area 5","areaSquareMetres":126},{"id":"lab-cell-1-6","label":"Quality work area 6","areaSquareMetres":126},{"id":"lab-cell-2-1","label":"Quality work area 7","areaSquareMetres":126},{"id":"lab-cell-2-2","label":"Quality work area 8","areaSquareMetres":126},{"id":"lab-cell-2-3","label":"Quality work area 9","areaSquareMetres":126},{"id":"lab-cell-2-4","label":"Quality work area 10","areaSquareMetres":126},{"id":"lab-cell-2-5","label":"Quality work area 11","areaSquareMetres":126},{"id":"lab-cell-2-6","label":"Quality work area 12","areaSquareMetres":126},{"id":"lab-cell-3-1","label":"Quality work area 13","areaSquareMetres":126},{"id":"lab-cell-3-2","label":"Quality work area 14","areaSquareMetres":126},{"id":"lab-cell-3-3","label":"Quality work area 15","areaSquareMetres":126},{"id":"lab-cell-3-4","label":"Quality work area 16","areaSquareMetres":126},{"id":"lab-cell-3-5","label":"Quality work area 17","areaSquareMetres":126},{"id":"lab-cell-3-6","label":"Quality work area 18","areaSquareMetres":126},{"id":"sample-drop","label":"Laboratory sample drop","areaSquareMetres":9,"overlaps":[{"id":"service-corridor","squareMetres":9}]},{"id":"staff-lounge-86","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-100","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-114","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-128","label":"Staff break area","areaSquareMetres":56}],"tags":[{"tag":"passage","zones":1,"areaSquareMetres":1260}],"markings":[],"parts":[{"kind":"chair","name":"Chair","count":76},{"kind":"cabinet","name":"Cabinet","count":36},{"kind":"machine","name":"Machine","count":36},{"kind":"workbench","name":"Workbench","count":36},{"kind":"screen","name":"Screen","count":28},{"kind":"zone","name":"Floor zone","count":24},{"kind":"wall","name":"Wall","count":22,"lengthMetres":590.8},{"kind":"shelf","name":"Shelf","count":18},{"kind":"fridge","name":"Fridge","count":18},{"kind":"washbasin","name":"Washbasin","count":18},{"kind":"sign","name":"Sign","count":18},{"kind":"platform_trolley","name":"Platform trolley","count":18},{"kind":"crate_stack","name":"Stack of crates","count":18},{"kind":"window","name":"Window","count":16},{"kind":"table","name":"Table","count":10},{"kind":"sofa","name":"Sofa","count":8},{"kind":"round_table","name":"Round table","count":4},{"kind":"planter","name":"Planter","count":4},{"kind":"gate","name":"Gate","count":2}],"partCount":410}],"definitions":{"floorArea":"Floor outline (or width × depth) less holes; parts such as walls are not subtracted.","zoneArea":"The zone footprint (turned or polygonal) that lies on the floor; offFloorSquareMetres is the rest.","overlaps":"Each zone keeps its whole area; zonedSquareMetres and tag areas count overlapping zones once; zoneOverlapSquareMetres is the double count in the zone rows.","tags":"Union of the zones with the tag on each floor, summed over floors; a zone counts under each of its tags.","uses":"Floor areas by their space type (scene kind): office, facility / retail, home, factory / warehouse.","levelsAndBuildings":"Sums of their floor areas; overlapping floor areas on one level are counted twice (Levels & areas warns)."},"tags":[{"tag":"passage","zones":2,"areaSquareMetres":2316}],"markings":[],"parts":[{"kind":"crate_stack","name":"Stack of crates","count":106},{"kind":"sign","name":"Sign","count":96},{"kind":"chair","name":"Chair","count":76},{"kind":"zone","name":"Floor zone","count":75},{"kind":"machine","name":"Machine","count":64},{"kind":"workbench","name":"Workbench","count":60},{"kind":"screen","name":"Screen","count":52},{"kind":"rack","name":"Pallet rack","count":50},{"kind":"shelf","name":"Shelf","count":42},{"kind":"platform_trolley","name":"Platform trolley","count":42},{"kind":"cabinet","name":"Cabinet","count":36},{"kind":"wall","name":"Wall","count":26,"lengthMetres":1070},{"kind":"dock_door","name":"Loading dock door","count":24},{"kind":"person","name":"Person (standing)","count":24},{"kind":"fridge","name":"Fridge","count":18},{"kind":"washbasin","name":"Washbasin","count":18},{"kind":"window","name":"Window","count":16},{"kind":"table","name":"Table","count":10},{"kind":"sofa","name":"Sofa","count":8},{"kind":"round_table","name":"Round table","count":4},{"kind":"gate","name":"Gate","count":4},{"kind":"planter","name":"Planter","count":4}]},"inventory":[{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-1","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"gate-1","label":"Gate","kind":"gate","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-2","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"gate-2","label":"Gate","kind":"gate","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-3","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":0,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-4","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":143.8,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"spine","label":"Material movement spine","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["passage"],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":12,"depth":88,"height":0.02},"position":{"x":67,"z":4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-1","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-1","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-2","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-2","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-3","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-3","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-4","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-4","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-5","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-5","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-6","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-6","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-7","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-7","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-8","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-8","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-9","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-9","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-10","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-10","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-11","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-11","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-12","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-12","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-13","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-13","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-14","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-14","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-15","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-15","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-16","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-16","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-17","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-17","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-18","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-18","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-19","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-19","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-20","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-20","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-21","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-21","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-22","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-22","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-23","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-23","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"shelf-24","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"platform_trolley-24","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-1","label":"Inbound bay 1","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":7,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-2","label":"Outbound bay 1","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":7,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-3","label":"Inbound bay 2","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":17,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-4","label":"Outbound bay 2","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":17,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-5","label":"Inbound bay 3","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":27,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-6","label":"Outbound bay 3","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":27,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-7","label":"Inbound bay 4","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":37,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-8","label":"Outbound bay 4","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":37,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-9","label":"Inbound bay 5","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":47,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-10","label":"Outbound bay 5","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":47,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-11","label":"Inbound bay 6","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":57,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-12","label":"Outbound bay 6","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":57,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-13","label":"Inbound bay 7","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":67,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-14","label":"Outbound bay 7","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":67,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-15","label":"Inbound bay 8","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":77,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-16","label":"Outbound bay 8","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":77,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-17","label":"Inbound bay 9","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":87,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-18","label":"Outbound bay 9","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":87,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-19","label":"Inbound bay 10","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":97,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-20","label":"Outbound bay 10","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":97,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-21","label":"Inbound bay 11","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":107,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-22","label":"Outbound bay 11","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":107,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-23","label":"Inbound bay 12","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":117,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-24","label":"Outbound bay 12","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":117,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"receiving","label":"Receiving handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"inspection","label":"Quality sample handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":26,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cold-store","label":"Cold-store handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"packing","label":"Packing handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":65,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dispatch","label":"Dispatch handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":85,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"mover-home","label":"Carrier parking","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":64,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-1-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":6.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-1-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":7.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-1-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":9.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-1-number","label":"IN 01","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":7.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-2-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":6.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-2-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":7.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-2-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":9.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-2-number","label":"OUT 01","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":7.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-3-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":16.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-3-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":17.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-3-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":19.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-3-number","label":"IN 02","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":17.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-4-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":16.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-4-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":17.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-4-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":19.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-4-number","label":"OUT 02","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":17.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-5-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":26.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-5-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":27.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-5-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":29.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-5-number","label":"IN 03","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":27.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-6-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":26.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-6-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":27.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-6-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":29.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-6-number","label":"OUT 03","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":27.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-7-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":36.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-7-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":37.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-7-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":39.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-7-number","label":"IN 04","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":37.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-8-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":36.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-8-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":37.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-8-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":39.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-8-number","label":"OUT 04","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":37.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-9-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":46.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-9-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":47.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-9-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":49.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-9-number","label":"IN 05","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":47.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-10-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":46.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-10-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":47.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-10-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":49.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-10-number","label":"OUT 05","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":47.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-11-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":56.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-11-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":57.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-11-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":59.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-11-number","label":"IN 06","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":57.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-12-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":56.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-12-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":57.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-12-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":59.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-12-number","label":"OUT 06","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":57.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-13-number","label":"IN 07 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":67.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-14-number","label":"OUT 07 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":67.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-15-number","label":"IN 08 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":77.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-16-number","label":"OUT 08 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":77.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-17-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":86.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-17-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":87.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-17-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":89.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-17-number","label":"IN 09","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":87.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-18-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":86.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-18-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":87.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-18-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":89.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-18-number","label":"OUT 09","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":87.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-19-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":96.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-19-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":97.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-19-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":99.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-19-number","label":"IN 10","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":97.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-20-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":96.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-20-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":97.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-20-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":99.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-20-number","label":"OUT 10","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":97.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-21-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":106.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-21-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":107.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-21-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":109.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-21-number","label":"IN 11","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":107.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-22-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":106.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-22-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":107.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-22-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":109.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-22-number","label":"OUT 11","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":107.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-23-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":116.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-23-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":117.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-23-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":119.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-23-number","label":"IN 12","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":117.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-24-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":116.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-24-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":117.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-24-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":119.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"dock_door-24-number","label":"OUT 12","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":117.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-1-number","label":"CHILL 01 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-2-number","label":"CHILL 02 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-3-number","label":"CHILL 03 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-4-number","label":"CHILL 04 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-5-number","label":"CHILL 05 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-6-number","label":"CHILL 06 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-7-number","label":"CHILL 07 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-8-number","label":"CHILL 08 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-9-number","label":"CHILL 09 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-1-10-number","label":"CHILL 10 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-1-number","label":"CHILL 11 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-2-number","label":"CHILL 12 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-3-number","label":"CHILL 13 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-4-number","label":"CHILL 14 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-5-number","label":"CHILL 15 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-6-number","label":"CHILL 16 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-7-number","label":"CHILL 17 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-8-number","label":"CHILL 18 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-9-number","label":"CHILL 19 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-2-10-number","label":"CHILL 20 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-1-number","label":"CHILL 21 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-2-number","label":"CHILL 22 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-3-number","label":"CHILL 23 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-4-number","label":"CHILL 24 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-5-number","label":"CHILL 25 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-6-number","label":"CHILL 26 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-7-number","label":"CHILL 27 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-8-number","label":"CHILL 28 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-9-number","label":"CHILL 29 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-3-10-number","label":"CHILL 30 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-1-number","label":"CHILL 31 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-2-number","label":"CHILL 32 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-3-number","label":"CHILL 33 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-4-number","label":"CHILL 34 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-5-number","label":"CHILL 35 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-6-number","label":"CHILL 36 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-7-number","label":"CHILL 37 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-8-number","label":"CHILL 38 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-9-number","label":"CHILL 39 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-4-10-number","label":"CHILL 40 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-1-number","label":"CHILL 41 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-2-number","label":"CHILL 42 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-3-number","label":"CHILL 43 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-4-number","label":"CHILL 44 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-5-number","label":"CHILL 45 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-6-number","label":"CHILL 46 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-7-number","label":"CHILL 47 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-8-number","label":"CHILL 48 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-9-number","label":"CHILL 49 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"rack-5-10-number","label":"CHILL 50 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-19-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-20-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-21-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-22-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-23-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-24-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-unit-7","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":7,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-label-7","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":7.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-unit-23","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":23,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-label-23","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":23.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-unit-39","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":39,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-label-39","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":39.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-unit-55","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":55,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cooling-label-55","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":55.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-1","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"gate-1","label":"Gate","kind":"gate","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-2","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"gate-2","label":"Gate","kind":"gate","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-3","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":0,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"wall-4","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":143.8,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"service-corridor","label":"Staff and service corridor","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":["passage"],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":15,"depth":84,"height":0.02},"position":{"x":64,"z":6,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1","label":"Quality work area 1","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-1","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-1","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-1","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-2","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2","label":"Quality work area 2","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-2","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-2","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-3","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-4","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3","label":"Quality work area 3","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-3","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-3","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-5","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-6","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4","label":"Quality work area 4","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-4","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-4","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-7","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-8","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5","label":"Quality work area 5","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-5","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-5","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-9","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-10","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6","label":"Quality work area 6","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-6","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-6","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-11","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-12","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1","label":"Quality work area 7","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-7","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-7","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-13","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-14","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2","label":"Quality work area 8","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-8","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-8","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-15","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-16","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3","label":"Quality work area 9","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-9","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-9","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-17","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-18","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4","label":"Quality work area 10","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-10","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-10","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-19","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-20","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5","label":"Quality work area 11","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-11","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-11","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-21","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-22","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6","label":"Quality work area 12","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-12","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-12","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-23","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-24","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1","label":"Quality work area 13","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-13","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-13","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-25","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-26","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2","label":"Quality work area 14","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-14","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-14","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-27","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-28","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3","label":"Quality work area 15","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-15","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-15","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-29","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-30","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4","label":"Quality work area 16","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-16","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-16","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-31","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-32","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5","label":"Quality work area 17","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-17","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-17","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-33","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-34","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6","label":"Quality work area 18","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"workbench-18","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"cabinet-18","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-35","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-36","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-1","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":84,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-37","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-38","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-39","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-40","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-2","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":91,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-41","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-42","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-43","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-44","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-3","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":98,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-45","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-46","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-47","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-48","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-4","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":105,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-49","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-50","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-51","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-52","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-5","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":112,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-53","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-54","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-55","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-56","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-6","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":84,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-57","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-58","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-59","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-60","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-7","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":91,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-61","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-62","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-63","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-64","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-8","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":98,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-65","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-66","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-67","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-68","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-9","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":105,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-69","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-70","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-71","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-72","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-10","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":112,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-73","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-74","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-75","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"chair-76","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"sample-drop","label":"Laboratory sample drop","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":69,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-7-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":7,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-7-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":7,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-23-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":23,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-23-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":23,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-39-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":39,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-39-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":39,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-55-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":55,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-55-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":55,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-85-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":85,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-85-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":85,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-101-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":101,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-101-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":101,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-117-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":117,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-117-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":117,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-133-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":133,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-window-133-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":133,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-sign","label":"QUALITY LAB 01","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-sign","label":"QUALITY LAB 02","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-sign","label":"QUALITY LAB 03","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-sign","label":"QUALITY LAB 04","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-sign","label":"QUALITY LAB 05","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-sign","label":"QUALITY LAB 06","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-1-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-sign","label":"QUALITY LAB 07","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-sign","label":"QUALITY LAB 08","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-sign","label":"QUALITY LAB 09","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-sign","label":"QUALITY LAB 10","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-sign","label":"QUALITY LAB 11","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-sign","label":"QUALITY LAB 12","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-2-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-sign","label":"QUALITY LAB 13","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-sign","label":"QUALITY LAB 14","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-sign","label":"QUALITY LAB 15","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-sign","label":"QUALITY LAB 16","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-sign","label":"QUALITY LAB 17","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-sign","label":"QUALITY LAB 18","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"lab-cell-3-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-1-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":84.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-2-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":91.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-3-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":98.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-4-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":105.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-5-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":112.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-6-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":84.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-7-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":91.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-8-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":98.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-9-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":105.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"table-10-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":112.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-lounge-86","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":85,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-86","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":86,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-return-86","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":86,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-coffee-86","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":86.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-plant-86","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":90,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-lounge-100","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":99,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-100","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":100,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-return-100","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":100,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-coffee-100","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":100.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-plant-100","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":104,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-lounge-114","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":113,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-114","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":114,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-return-114","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":114,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-coffee-114","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":114.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-plant-114","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":118,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-lounge-128","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":127,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-128","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":128,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-sofa-return-128","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":128,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-coffee-128","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":128.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"staff-plant-128","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":132,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}}],"checks":{"minClearance":0.9,"floorsChecked":2,"linksChecked":2,"floors":[],"floorOverlaps":[],"links":[],"limits":[],"totals":{"floor_overlap":0}},"drawings":[{"title":"L1 · Receiving, chilled storage and dispatch — floor plan","floors":["NX-L1"],"spaceHash":"fnv1a-fc82ac11","inputHash":"fnv1a-b24498c7","scale":600,"paper":"A3"},{"title":"L2 · Quality laboratory and staff operations — floor plan","floors":["NX-L2"],"spaceHash":"fnv1a-fc82ac11","inputHash":"fnv1a-b24498c7","scale":600,"paper":"A3"}],"picture":{"status":"omitted","reason":"not_requested"}},{"id":"northstar-detail-layout-b","name":"Detailed · 6 carriers · 3 inspection · 4 packing slots","createdAt":"2026-10-15T10:37:28.947Z","inputHash":"fnv1a-acf97ffc","spaceHash":"fnv1a-70a8a930","brief":{"purpose":"Synthetic operational planning example: Northstar Cold-chain Cross-dock","decision":"Compare the stated capacity and layout changes under identical demand.","preparedFor":"Facility operations planner","sources":[{"id":"synthetic","title":"Synthetic operating brief","kind":"assumption","note":"No real site measurements, certification, demand forecast or ROI."}],"facts":[{"id":"assumption-1","label":"Operating assumption 1","value":"Two 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-2","label":"Operating assumption 2","value":"24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-3","label":"Operating assumption 3","value":"120 loads at 15 s intervals; two-hour observation.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-4","label":"Operating assumption 4","value":"Inspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-5","label":"Operating assumption 5","value":"Carriers hold loads through all steps and return empty before becoming available.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-6","label":"Operating assumption 6","value":"The staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.","status":"assumed","sourceId":"synthetic","decisionCritical":false}],"requirements":["Preserve the synthetic dimensions and declared demand.","Check real clearances, service times and demand before any operational use."],"fixedParts":[]},"underlays":[],"quantities":{"units":{"length":"m","area":"m²"},"site":{"floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4,"parts":855},"levels":[{"level":0,"label":"L1","floors":["NX-L1"],"floorAreaSquareMetres":13824,"zonedSquareMetres":2391.4},{"level":1,"label":"L2","floors":["NX-L2"],"floorAreaSquareMetres":13824,"zonedSquareMetres":3752}],"structures":[{"id":"NX","name":"Cross-dock and quality operations","floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4}],"uses":[{"use":"facility","name":"Facility / retail","floors":["NX-L1","NX-L2"],"floorAreaSquareMetres":27648,"zonedSquareMetres":6143.4}],"floors":[{"id":"NX-L1","name":"Receiving, chilled storage and dispatch","level":0,"label":"L1","structure":"NX","use":"facility","floorAreaSquareMetres":13824,"zonedSquareMetres":2391.4,"unzonedSquareMetres":11432.6,"zoneOverlapSquareMetres":45,"zones":[{"id":"spine","label":"Material movement spine","tags":["passage"],"areaSquareMetres":1056,"overlaps":[{"id":"receiving","squareMetres":9},{"id":"inspection","squareMetres":9},{"id":"cold-store","squareMetres":9},{"id":"packing","squareMetres":9},{"id":"dispatch","squareMetres":9}]},{"id":"receiving","label":"Receiving handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"inspection","label":"Quality sample handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"cold-store","label":"Cold-store handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"packing","label":"Packing handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"dispatch","label":"Dispatch handoff","areaSquareMetres":9,"overlaps":[{"id":"spine","squareMetres":9}]},{"id":"mover-home","label":"Carrier parking","areaSquareMetres":9},{"id":"dock_door-1-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-2-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-3-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-4-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-5-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-6-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-7-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-8-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-9-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-10-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-11-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-12-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-17-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-18-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-19-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-20-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-21-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-22-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-23-staging","label":"Inbound pallet staging","areaSquareMetres":20.24},{"id":"dock_door-24-staging","label":"Outbound pallet staging","areaSquareMetres":20.24},{"id":"workbench-1-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-2-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-3-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-4-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-5-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-6-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-7-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-8-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-9-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-10-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-11-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-12-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-13-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-14-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-15-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-16-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-17-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-18-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-19-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-20-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-21-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-22-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-23-station","label":"Packing work area","areaSquareMetres":38.4},{"id":"workbench-24-station","label":"Packing work area","areaSquareMetres":38.4}],"tags":[{"tag":"passage","zones":1,"areaSquareMetres":1056}],"markings":[],"parts":[{"kind":"crate_stack","name":"Stack of crates","count":88},{"kind":"sign","name":"Sign","count":78},{"kind":"zone","name":"Floor zone","count":51},{"kind":"rack","name":"Pallet rack","count":50},{"kind":"machine","name":"Machine","count":28},{"kind":"shelf","name":"Shelf","count":24},{"kind":"workbench","name":"Workbench","count":24},{"kind":"dock_door","name":"Loading dock door","count":24},{"kind":"screen","name":"Screen","count":24},{"kind":"person","name":"Person (standing)","count":24},{"kind":"platform_trolley","name":"Platform trolley","count":24},{"kind":"wall","name":"Wall","count":4,"lengthMetres":479.2},{"kind":"gate","name":"Gate","count":2}],"partCount":445},{"id":"NX-L2","name":"Quality laboratory and staff operations","level":1,"label":"L2","structure":"NX","use":"facility","floorAreaSquareMetres":13824,"zonedSquareMetres":3752,"unzonedSquareMetres":10072,"zoneOverlapSquareMetres":9,"zones":[{"id":"service-corridor","label":"Staff and service corridor","tags":["passage"],"areaSquareMetres":1260,"overlaps":[{"id":"sample-drop","squareMetres":9}]},{"id":"lab-cell-1-1","label":"Quality work area 1","areaSquareMetres":126},{"id":"lab-cell-1-2","label":"Quality work area 2","areaSquareMetres":126},{"id":"lab-cell-1-3","label":"Quality work area 3","areaSquareMetres":126},{"id":"lab-cell-1-4","label":"Quality work area 4","areaSquareMetres":126},{"id":"lab-cell-1-5","label":"Quality work area 5","areaSquareMetres":126},{"id":"lab-cell-1-6","label":"Quality work area 6","areaSquareMetres":126},{"id":"lab-cell-2-1","label":"Quality work area 7","areaSquareMetres":126},{"id":"lab-cell-2-2","label":"Quality work area 8","areaSquareMetres":126},{"id":"lab-cell-2-3","label":"Quality work area 9","areaSquareMetres":126},{"id":"lab-cell-2-4","label":"Quality work area 10","areaSquareMetres":126},{"id":"lab-cell-2-5","label":"Quality work area 11","areaSquareMetres":126},{"id":"lab-cell-2-6","label":"Quality work area 12","areaSquareMetres":126},{"id":"lab-cell-3-1","label":"Quality work area 13","areaSquareMetres":126},{"id":"lab-cell-3-2","label":"Quality work area 14","areaSquareMetres":126},{"id":"lab-cell-3-3","label":"Quality work area 15","areaSquareMetres":126},{"id":"lab-cell-3-4","label":"Quality work area 16","areaSquareMetres":126},{"id":"lab-cell-3-5","label":"Quality work area 17","areaSquareMetres":126},{"id":"lab-cell-3-6","label":"Quality work area 18","areaSquareMetres":126},{"id":"sample-drop","label":"Laboratory sample drop","areaSquareMetres":9,"overlaps":[{"id":"service-corridor","squareMetres":9}]},{"id":"staff-lounge-86","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-100","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-114","label":"Staff break area","areaSquareMetres":56},{"id":"staff-lounge-128","label":"Staff break area","areaSquareMetres":56}],"tags":[{"tag":"passage","zones":1,"areaSquareMetres":1260}],"markings":[],"parts":[{"kind":"chair","name":"Chair","count":76},{"kind":"cabinet","name":"Cabinet","count":36},{"kind":"machine","name":"Machine","count":36},{"kind":"workbench","name":"Workbench","count":36},{"kind":"screen","name":"Screen","count":28},{"kind":"zone","name":"Floor zone","count":24},{"kind":"wall","name":"Wall","count":22,"lengthMetres":590.8},{"kind":"shelf","name":"Shelf","count":18},{"kind":"fridge","name":"Fridge","count":18},{"kind":"washbasin","name":"Washbasin","count":18},{"kind":"sign","name":"Sign","count":18},{"kind":"platform_trolley","name":"Platform trolley","count":18},{"kind":"crate_stack","name":"Stack of crates","count":18},{"kind":"window","name":"Window","count":16},{"kind":"table","name":"Table","count":10},{"kind":"sofa","name":"Sofa","count":8},{"kind":"round_table","name":"Round table","count":4},{"kind":"planter","name":"Planter","count":4},{"kind":"gate","name":"Gate","count":2}],"partCount":410}],"definitions":{"floorArea":"Floor outline (or width × depth) less holes; parts such as walls are not subtracted.","zoneArea":"The zone footprint (turned or polygonal) that lies on the floor; offFloorSquareMetres is the rest.","overlaps":"Each zone keeps its whole area; zonedSquareMetres and tag areas count overlapping zones once; zoneOverlapSquareMetres is the double count in the zone rows.","tags":"Union of the zones with the tag on each floor, summed over floors; a zone counts under each of its tags.","uses":"Floor areas by their space type (scene kind): office, facility / retail, home, factory / warehouse.","levelsAndBuildings":"Sums of their floor areas; overlapping floor areas on one level are counted twice (Levels & areas warns)."},"tags":[{"tag":"passage","zones":2,"areaSquareMetres":2316}],"markings":[],"parts":[{"kind":"crate_stack","name":"Stack of crates","count":106},{"kind":"sign","name":"Sign","count":96},{"kind":"chair","name":"Chair","count":76},{"kind":"zone","name":"Floor zone","count":75},{"kind":"machine","name":"Machine","count":64},{"kind":"workbench","name":"Workbench","count":60},{"kind":"screen","name":"Screen","count":52},{"kind":"rack","name":"Pallet rack","count":50},{"kind":"shelf","name":"Shelf","count":42},{"kind":"platform_trolley","name":"Platform trolley","count":42},{"kind":"cabinet","name":"Cabinet","count":36},{"kind":"wall","name":"Wall","count":26,"lengthMetres":1070},{"kind":"dock_door","name":"Loading dock door","count":24},{"kind":"person","name":"Person (standing)","count":24},{"kind":"fridge","name":"Fridge","count":18},{"kind":"washbasin","name":"Washbasin","count":18},{"kind":"window","name":"Window","count":16},{"kind":"table","name":"Table","count":10},{"kind":"sofa","name":"Sofa","count":8},{"kind":"round_table","name":"Round table","count":4},{"kind":"gate","name":"Gate","count":4},{"kind":"planter","name":"Planter","count":4}]},"inventory":[{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-1","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"gate-1","label":"Gate","kind":"gate","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-2","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"gate-2","label":"Gate","kind":"gate","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-3","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":0,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-4","label":"Wall","kind":"wall","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":143.8,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"spine","label":"Material movement spine","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["passage"],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":12,"depth":88,"height":0.02},"position":{"x":67,"z":4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":32,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":56,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-1","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":5,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-2","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":10.6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-3","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":16.2,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-4","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":21.8,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-5","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":27.4,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-6","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":33,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-7","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":38.6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-8","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":44.2,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-9","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":49.8,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-10","label":"Chilled rack bay","kind":"rack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":["rack-bay"],"source":"assumed","note":"Assumed six load positions per bay. Capacity is declared, not inferred from the visual geometry.","dimensions":{"width":3.6,"depth":7,"height":5.5},"position":{"x":55.4,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-1","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-1","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-2","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-2","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-3","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-3","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-4","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-4","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-5","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-5","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-6","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-6","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":25.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-7","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-7","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-8","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-8","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-9","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-9","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-10","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-10","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-11","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-11","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-12","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":37,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-12","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":40.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-13","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-13","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-14","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-14","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-15","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-15","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-16","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-16","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-17","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-17","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-18","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":52,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-18","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":55.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":83,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-19","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":87.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-19","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":83,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":91.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-20","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":96,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-20","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":91.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":100,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-21","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":104.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-21","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":100,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":108.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-22","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":113,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-22","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":108.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":117,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-23","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":121.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-23","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":117,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24","label":"Packing cell","kind":"workbench","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":2,"height":0.9},"position":{"x":125.5,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"shelf-24","label":"Packaging supply","kind":"shelf","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1,"depth":2,"height":1.8},"position":{"x":130,"z":67,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"platform_trolley-24","label":"Packing trolley","kind":"platform_trolley","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":1.2,"depth":0.8,"height":0.9},"position":{"x":125.5,"z":70.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-1","label":"Inbound bay 1","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":7,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-2","label":"Outbound bay 1","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":7,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-3","label":"Inbound bay 2","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":17,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-4","label":"Outbound bay 2","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":17,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-5","label":"Inbound bay 3","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":27,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-6","label":"Outbound bay 3","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":27,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-7","label":"Inbound bay 4","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":37,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-8","label":"Outbound bay 4","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":37,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-9","label":"Inbound bay 5","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":47,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-10","label":"Outbound bay 5","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":47,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-11","label":"Inbound bay 6","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":57,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-12","label":"Outbound bay 6","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":57,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-13","label":"Inbound bay 7","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":67,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-14","label":"Outbound bay 7","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":67,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-15","label":"Inbound bay 8","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":77,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-16","label":"Outbound bay 8","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":77,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-17","label":"Inbound bay 9","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":87,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-18","label":"Outbound bay 9","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":87,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-19","label":"Inbound bay 10","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":97,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-20","label":"Outbound bay 10","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":97,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-21","label":"Inbound bay 11","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":107,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-22","label":"Outbound bay 11","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":107,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-23","label":"Inbound bay 12","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":117,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-24","label":"Outbound bay 12","kind":"dock_door","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":0.25,"height":4},"position":{"x":117,"z":95.75,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"receiving","label":"Receiving handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"inspection","label":"Quality sample handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":26,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cold-store","label":"Cold-store handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"packing","label":"Packing handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dispatch","label":"Dispatch handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":85,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"mover-home","label":"Carrier parking","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":64,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-1-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":6.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-1-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":7.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-1-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":9.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-1-number","label":"IN 01","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":7.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-2-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":6.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-2-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":7.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-2-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":9.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-2-number","label":"OUT 01","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":7.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-3-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":16.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-3-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":17.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-3-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":19.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-3-number","label":"IN 02","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":17.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-4-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":16.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-4-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":17.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-4-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":19.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-4-number","label":"OUT 02","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":17.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-5-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":26.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-5-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":27.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-5-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":29.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-5-number","label":"IN 03","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":27.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-6-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":26.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-6-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":27.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-6-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":29.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-6-number","label":"OUT 03","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":27.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-7-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":36.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-7-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":37.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-7-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":39.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-7-number","label":"IN 04","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":37.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-8-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":36.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-8-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":37.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-8-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":39.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-8-number","label":"OUT 04","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":37.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-9-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":46.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-9-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":47.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-9-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":49.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-9-number","label":"IN 05","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":47.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-10-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":46.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-10-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":47.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-10-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":49.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-10-number","label":"OUT 05","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":47.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-11-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":56.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-11-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":57.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-11-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":59.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-11-number","label":"IN 06","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":57.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-12-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":56.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-12-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":57.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-12-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":59.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-12-number","label":"OUT 06","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":57.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-13-number","label":"IN 07 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":67.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-14-number","label":"OUT 07 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":67.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-15-number","label":"IN 08 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":77.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-16-number","label":"OUT 08 · KEEP CLEAR","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":77.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-17-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":86.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-17-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":87.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-17-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":89.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-17-number","label":"IN 09","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":87.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-18-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":86.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-18-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":87.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-18-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":89.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-18-number","label":"OUT 09","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":87.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-19-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":96.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-19-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":97.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-19-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":99.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-19-number","label":"IN 10","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":97.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-20-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":96.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-20-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":97.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-20-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":99.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-20-number","label":"OUT 10","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":97.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-21-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":106.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-21-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":107.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-21-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":109.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-21-number","label":"IN 11","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":107.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-22-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":106.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-22-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":107.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-22-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":109.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-22-number","label":"OUT 11","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":107.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-23-staging","label":"Inbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":116.7,"z":3,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-23-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":117.3,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-23-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":119.5,"z":4.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-23-number","label":"IN 12","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":117.4,"z":0.21,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-24-staging","label":"Outbound pallet staging","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4.6,"depth":4.4,"height":0.02},"position":{"x":116.7,"z":88,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-24-pallet-0","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":117.3,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-24-pallet-1","label":"Staged temperature-controlled load","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":1.2,"depth":1,"height":1.05},"position":{"x":119.5,"z":89.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"dock_door-24-number","label":"OUT 12","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.2,"depth":0.04,"height":0.4},"position":{"x":117.4,"z":95.74,"y":3.1,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-1-number","label":"CHILL 01 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-2-number","label":"CHILL 02 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-3-number","label":"CHILL 03 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-4-number","label":"CHILL 04 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-5-number","label":"CHILL 05 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-6-number","label":"CHILL 06 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-7-number","label":"CHILL 07 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-8-number","label":"CHILL 08 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-9-number","label":"CHILL 09 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-1-10-number","label":"CHILL 10 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":27.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-1-number","label":"CHILL 11 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-2-number","label":"CHILL 12 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-3-number","label":"CHILL 13 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-4-number","label":"CHILL 14 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-5-number","label":"CHILL 15 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-6-number","label":"CHILL 16 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-7-number","label":"CHILL 17 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-8-number","label":"CHILL 18 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-9-number","label":"CHILL 19 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-2-10-number","label":"CHILL 20 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":39.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-1-number","label":"CHILL 21 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-2-number","label":"CHILL 22 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-3-number","label":"CHILL 23 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-4-number","label":"CHILL 24 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-5-number","label":"CHILL 25 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-6-number","label":"CHILL 26 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-7-number","label":"CHILL 27 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-8-number","label":"CHILL 28 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-9-number","label":"CHILL 29 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-3-10-number","label":"CHILL 30 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":51.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-1-number","label":"CHILL 31 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-2-number","label":"CHILL 32 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-3-number","label":"CHILL 33 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-4-number","label":"CHILL 34 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-5-number","label":"CHILL 35 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-6-number","label":"CHILL 36 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-7-number","label":"CHILL 37 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-8-number","label":"CHILL 38 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-9-number","label":"CHILL 39 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-4-10-number","label":"CHILL 40 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":63.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-1-number","label":"CHILL 41 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":5.3,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-2-number","label":"CHILL 42 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":10.9,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-3-number","label":"CHILL 43 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":16.5,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-4-number","label":"CHILL 44 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":22.1,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-5-number","label":"CHILL 45 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":27.7,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-6-number","label":"CHILL 46 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":33.3,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-7-number","label":"CHILL 47 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":38.9,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-8-number","label":"CHILL 48 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":44.5,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-9-number","label":"CHILL 49 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":50.099999999999994,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"rack-5-10-number","label":"CHILL 50 · 6 POSITIONS","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.04,"height":0.4},"position":{"x":55.699999999999996,"z":75.01,"y":1.75,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":21.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":22.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":22.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":23.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":25.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":36.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":37.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":37.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":38.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":40.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":51.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":52.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":52.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":53.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":55.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":82.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":85.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":83.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":84.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":85.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-19-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":85,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":91.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":94,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":91.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":92.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":94.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-20-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":93.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":99.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":102.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":100.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":101.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":102.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-21-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":102,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":108.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":111,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":108.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":109.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":111.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-22-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":110.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":116.6,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":119.5,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":117.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":118.3,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":119.6,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-23-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":119,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-station","label":"Packing work area","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":6.4,"depth":6,"height":0.02},"position":{"x":125.1,"z":66.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-terminal","label":"Packing order terminal","kind":"screen","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.2,"height":0.5},"position":{"x":128,"z":67.25,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-carton-0","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.35},"position":{"x":125.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-carton-1","label":"Cartons on packing bench","kind":"crate_stack","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.7,"depth":0.7,"height":0.55},"position":{"x":126.8,"z":67.7,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-scanner","label":"Bench scale and label printer","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.65,"depth":0.55,"height":0.3},"position":{"x":128.1,"z":68.05,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-24-operator","label":"Packing operator","kind":"person","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":1.7},"position":{"x":127.5,"z":70.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-unit-7","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":7,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-label-7","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":7.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-unit-23","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":23,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-label-23","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":23.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-unit-39","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":39,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-label-39","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":39.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-unit-55","label":"Cold-store evaporator","kind":"machine","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":4,"depth":1,"height":1.1},"position":{"x":55,"z":14,"y":5.5,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cooling-label-55","label":"CHILLED STORAGE","kind":"sign","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":null,"note":null,"dimensions":{"width":3.6,"depth":0.04,"height":0.4},"position":{"x":55.2,"z":15.02,"y":5.7,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-1","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"gate-1","label":"Gate","kind":"gate","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":0,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-2","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":144,"depth":0.2,"height":4},"position":{"x":0,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"gate-2","label":"Gate","kind":"gate","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":2},"position":{"x":69,"z":95.8,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-3","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":0,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"wall-4","label":"Wall","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.2,"depth":95.6,"height":4},"position":{"x":143.8,"z":0.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"service-corridor","label":"Staff and service corridor","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":["passage"],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":15,"depth":84,"height":0.02},"position":{"x":64,"z":6,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1","label":"Quality work area 1","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-1","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-1","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-1","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-2","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2","label":"Quality work area 2","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-2","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-2","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-3","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-4","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3","label":"Quality work area 3","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-3","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-3","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-5","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-6","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4","label":"Quality work area 4","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-4","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-4","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-7","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-8","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5","label":"Quality work area 5","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-5","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-5","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-9","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-10","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6","label":"Quality work area 6","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":10,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-6","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-6","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-11","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-12","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1","label":"Quality work area 7","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-7","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-7","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-13","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-14","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2","label":"Quality work area 8","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-8","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-8","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-15","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-16","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3","label":"Quality work area 9","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-9","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-9","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-17","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-18","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4","label":"Quality work area 10","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-10","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-10","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-19","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-20","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5","label":"Quality work area 11","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-11","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-11","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-21","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-22","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6","label":"Quality work area 12","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":34,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-12","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":36,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-12","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-23","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-24","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1","label":"Quality work area 13","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":5,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-13","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":6,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-13","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":6,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-25","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":6,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-26","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2","label":"Quality work area 14","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":14,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-14","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":15,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-14","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":15,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-27","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":15,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-28","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":17,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3","label":"Quality work area 15","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":23,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-15","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":24,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-15","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":24,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-29","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":24,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-30","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":26,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4","label":"Quality work area 16","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":32,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-16","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":33,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-16","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":33,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-31","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":33,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-32","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":35,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5","label":"Quality work area 17","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":41,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-17","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":42,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-17","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":42,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-33","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":42,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-34","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":44,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6","label":"Quality work area 18","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":7,"depth":18,"height":0.02},"position":{"x":50,"z":58,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"workbench-18","label":"Laboratory workbench","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":4,"depth":1,"height":0.9},"position":{"x":51,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"cabinet-18","label":"Sample cabinet","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":2,"depth":1,"height":1.8},"position":{"x":51,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-35","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":51,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-36","label":"Laboratory chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":0.5,"depth":0.5,"height":0.85},"position":{"x":53,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-1","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":84,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-37","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-38","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-39","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-40","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-2","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":91,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-41","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-42","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-43","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-44","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-3","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":98,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-45","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-46","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-47","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-48","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-4","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":105,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-49","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-50","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-51","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-52","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-5","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":112,"z":9.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-53","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-54","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-55","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":9,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-56","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":10.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-6","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":84,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-57","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-58","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":84.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-59","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-60","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":85.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-7","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":91,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-61","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-62","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":91.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-63","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-64","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":92.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-8","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":98,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-65","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-66","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":98.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-67","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-68","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":99.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-9","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":105,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-69","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-70","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":105.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-71","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-72","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":106.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-10","label":"Staff collaboration table","kind":"table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2,"depth":1,"height":0.74},"position":{"x":112,"z":24.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-73","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-74","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":112.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-75","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"chair-76","label":"Chair","kind":"chair","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.45,"depth":0.45,"height":0.85},"position":{"x":113.275,"z":25.55,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"sample-drop","label":"Laboratory sample drop","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":69,"z":12,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-7-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":7,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-7-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":7,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-23-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":23,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-23-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":23,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-39-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":39,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-39-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":39,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-55-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":55,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-55-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":55,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-85-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":85,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-85-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":85,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-101-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":101,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-101-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":101,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-117-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":117,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-117-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":117,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-133-0","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":133,"z":0,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-window-133-95.8","label":"Laboratory clerestory","kind":"window","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6,"depth":0.2,"height":1.6},"position":{"x":133,"z":95.8,"y":1.25,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-sign","label":"QUALITY LAB 01","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-sign","label":"QUALITY LAB 02","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-sign","label":"QUALITY LAB 03","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-sign","label":"QUALITY LAB 04","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-sign","label":"QUALITY LAB 05","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":10.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-sign","label":"QUALITY LAB 06","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":10.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":12.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":15,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":18,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":22,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":20,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":20.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":20.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":21,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-1-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":24,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-sign","label":"QUALITY LAB 07","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-sign","label":"QUALITY LAB 08","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-sign","label":"QUALITY LAB 09","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-sign","label":"QUALITY LAB 10","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-sign","label":"QUALITY LAB 11","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":34.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-sign","label":"QUALITY LAB 12","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":34.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":36.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":39,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":42,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":46,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":44,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":44.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":44.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":45,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-2-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":48,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":5.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-sign","label":"QUALITY LAB 13","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":5.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":8.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":6.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":9.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":9.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":6,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":6,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":6.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":7.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":9.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-1-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":6,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":14.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-sign","label":"QUALITY LAB 14","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":14.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":17.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":15.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":18.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":18.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":15,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":15,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":15.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":16.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":18.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-2-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":15,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":23.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-sign","label":"QUALITY LAB 15","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":23.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":26.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":24.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":27.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":27.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":24,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":24,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":24.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":25.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":27.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-3-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":24,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":32.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-sign","label":"QUALITY LAB 16","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":32.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":35.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":33.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":36.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":36.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":33,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":33,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":33.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":34.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":36.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-4-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":33,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":41.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-sign","label":"QUALITY LAB 17","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":41.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":44.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":42.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":45.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":45.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":42,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":42,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":42.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":43.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":45.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-5-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":42,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-back","label":"Laboratory service panel","kind":"wall","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":6.2,"depth":0.15,"height":2.5},"position":{"x":50.4,"z":58.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-sign","label":"QUALITY LAB 18","kind":"sign","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":5.4,"depth":0.04,"height":0.4},"position":{"x":50.8,"z":58.56,"y":1.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-terminal","label":"Sample analysis display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.15,"height":0.6},"position":{"x":53.8,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-analyser","label":"Bench sample analyser","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.7},"position":{"x":51.25,"z":60.1,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-fridge","label":"Retained sample refrigerator","kind":"fridge","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.8,"height":1.9},"position":{"x":54.8,"z":63,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-basin","label":"Laboratory handwash basin","kind":"washbasin","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.7,"height":0.9},"position":{"x":54.8,"z":66,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-cart","label":"Sample transport cart","kind":"platform_trolley","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1,"depth":0.7,"height":0.9},"position":{"x":51,"z":70,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-prep-bench","label":"Sample preparation island","kind":"workbench","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":0.9},"position":{"x":51,"z":68,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-prep-scale","label":"Sample weighing station","kind":"machine","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.6,"height":0.45},"position":{"x":51.15,"z":68.15,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-sample-trays","label":"Sample trays on preparation bench","kind":"crate_stack","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.9,"depth":0.6,"height":0.35},"position":{"x":52.3,"z":68.2,"y":0.9,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-retained-samples","label":"Retained sample shelving","kind":"shelf","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":4.8,"height":1.8},"position":{"x":54.8,"z":69,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"lab-cell-3-6-records","label":"Sample records and consumables","kind":"cabinet","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":2.6,"depth":1,"height":1.2},"position":{"x":51,"z":72,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-1-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":84.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-2-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":91.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-3-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":98.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-4-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":105.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-5-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":112.4,"z":9.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-6-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":84.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-7-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":91.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-8-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":98.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-9-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":105.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"table-10-screen","label":"Operations desk display","kind":"screen","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":0.18,"height":0.55},"position":{"x":112.4,"z":24.6,"y":0.74,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-lounge-86","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":85,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-86","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":86,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-return-86","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":86,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-coffee-86","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":86.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-plant-86","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":90,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-lounge-100","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":99,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-100","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":100,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-return-100","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":100,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-coffee-100","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":100.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-plant-100","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":104,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-lounge-114","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":113,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-114","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":114,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-return-114","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":114,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-coffee-114","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":114.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-plant-114","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":118,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-lounge-128","label":"Staff break area","kind":"zone","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":7,"depth":8,"height":0.02},"position":{"x":127,"z":48.5,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-128","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":128,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-sofa-return-128","label":"Staff break seating","kind":"sofa","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":3,"depth":0.95,"height":0.9},"position":{"x":128,"z":54.4,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-coffee-128","label":"Break table","kind":"round_table","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":1.1,"depth":1.1,"height":0.5},"position":{"x":128.8,"z":52.2,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}},{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"staff-plant-128","label":"Staff lounge planting","kind":"planter","floor":"NX-L2","floorName":"Quality laboratory and staff operations","structure":"NX","structureName":"Cross-dock and quality operations","level":1,"tags":[],"source":null,"note":null,"dimensions":{"width":0.8,"depth":0.8,"height":1.1},"position":{"x":132,"z":50,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":8}}],"checks":{"minClearance":0.9,"floorsChecked":2,"linksChecked":2,"floors":[],"floorOverlaps":[],"links":[],"limits":[],"totals":{"floor_overlap":0}},"drawings":[{"title":"L1 · Receiving, chilled storage and dispatch — floor plan","floors":["NX-L1"],"spaceHash":"fnv1a-70a8a930","inputHash":"fnv1a-acf97ffc","scale":600,"paper":"A3"},{"title":"L2 · Quality laboratory and staff operations — floor plan","floors":["NX-L2"],"spaceHash":"fnv1a-70a8a930","inputHash":"fnv1a-acf97ffc","scale":600,"paper":"A3"}],"picture":{"status":"omitted","reason":"not_requested"}}],"comparisons":[{"baseline":{"id":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7"},"candidate":{"id":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc"},"parts":{"changes":[{"id":"packing","status":"moved","from":{"optionId":"northstar-detail-layout-a","inputHash":"fnv1a-b24498c7","id":"packing","label":"Packing handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":65,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},"to":{"optionId":"northstar-detail-layout-b","inputHash":"fnv1a-acf97ffc","id":"packing","label":"Packing handoff","kind":"zone","floor":"NX-L1","floorName":"Receiving, chilled storage and dispatch","structure":"NX","structureName":"Cross-dock and quality operations","level":0,"tags":[],"source":"assumed","note":"Synthetic dimensions; confirm against a measured site plan.","dimensions":{"width":3,"depth":3,"height":0.02},"position":{"x":72,"z":60,"y":0,"rotation":0},"floorPosition":{"x":0,"z":0,"elevation":0}},"changes":[{"field":"z","from":65,"to":60}]}],"unchanged":854,"ambiguousIds":[]},"floors":[],"structures":[],"links":[],"fixedParts":[],"fixedChanges":[],"fixedFloors":[],"fixedConnections":[],"fixedFrameChanges":[]}],"evaluation":{"engineVersion":"design-static-1","evaluationHash":"fnv1a-9c49227a","baselineId":"northstar-detail-layout-a","criteria":[],"uncoveredRequirements":[{"index":0,"text":"Preserve the synthetic dimensions and declared demand."},{"index":1,"text":"Check real clearances, service times and demand before any operational use."}],"options":[{"id":"northstar-detail-layout-a","name":"Detailed · 3 carriers · 2 inspection · 2 packing slots","inputHash":"fnv1a-b24498c7","spaceHash":"fnv1a-fc82ac11","status":"unknown","measurements":[],"fixedChanges":[],"unknowns":[],"criticalUnknowns":[],"assumptions":[{"id":"assumption-1","label":"Operating assumption 1","value":"Two 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-2","label":"Operating assumption 2","value":"24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-3","label":"Operating assumption 3","value":"120 loads at 15 s intervals; two-hour observation.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-4","label":"Operating assumption 4","value":"Inspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-5","label":"Operating assumption 5","value":"Carriers hold loads through all steps and return empty before becoming available.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-6","label":"Operating assumption 6","value":"The staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.","status":"assumed","sourceId":"synthetic","decisionCritical":false}]},{"id":"northstar-detail-layout-b","name":"Detailed · 6 carriers · 3 inspection · 4 packing slots","inputHash":"fnv1a-acf97ffc","spaceHash":"fnv1a-70a8a930","status":"unknown","measurements":[],"fixedChanges":[],"unknowns":[],"criticalUnknowns":[],"assumptions":[{"id":"assumption-1","label":"Operating assumption 1","value":"Two 144 × 96 m floor plates, 27,648 m² gross; 8 m high ground floor.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-2","label":"Operating assumption 2","value":"24 vehicle bays, 50 rack bays × six declared load positions and 24 packing cells.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-3","label":"Operating assumption 3","value":"120 loads at 15 s intervals; two-hour observation.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-4","label":"Operating assumption 4","value":"Inspection 90 s, packing 150 s, each handling 30 s; carrier speed 1 m/s and radius 0.6 m.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-5","label":"Operating assumption 5","value":"Carriers hold loads through all steps and return empty before becoming available.","status":"assumed","sourceId":"synthetic","decisionCritical":false},{"id":"assumption-6","label":"Operating assumption 6","value":"The staff laboratory is layout only. Temperature, certification, vehicle conflicts and product safety are not calculated.","status":"assumed","sourceId":"synthetic","decisionCritical":false}]}],"status":"needs_confirmation","shortlist":[],"recommendation":null,"scope":"Only the supplied criteria and tested drawings. No queues, crowd physics, code compliance, real-site verification or global optimum. Assumptions remain conditional."},"costComparisons":[],"omittedCostComparisons":[]}